LEGIONELLA CONTAMINATION OF DENTAL-UNIT WATERS

被引:170
作者
ATLAS, RM [1 ]
WILLIAMS, JF [1 ]
HUNTINGTON, MK [1 ]
机构
[1] MICHIGAN STATE UNIV,DEPT MICROBIOL,E LANSING,MI 48824
关键词
D O I
10.1128/AEM.61.4.1208-1213.1995
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Water samples collected from 28 dental facilities in six U.S. states were examined for the presence of Legionella pneumophila and other Legionella spp. by the PCR-gene probe, fluorescent-antibody microscopic, and viable-plate-count detection methods. The PCR and fluorescent-antibody detection methods, which detect both viable and viable nonculturable Legionella spp., gave higher counts and rates of detection than the plate count method. By the PCR-gene probe detection method, Legionella spp. were detected in 68% of the dental-unit water samples and L. pneumophila was detected in 8%. Concentrations of legionella spp, in dental unit water reached 1,000 organisms per ml or more in 36% of the samples, and 19% of the samples were in the category of 10,000/ml or above, L. pneumophila, when present in dental-unit water, never reached concentrations of 1,000/ml or more. Microscopic examination with fluorescent-antibody staining indicated that the contamination was in the dental-unit water lines rather than in the handpieces. Legionella spp. were present in 61% of potable water samples collected for comparative analysis from domestic and institutional faucets and drinking fountains; this percentage was not significantly different from the rate of detection of Legionella spp. in dental-unit water. However, in only 4% of the potable water samples did Legionella spp. reach concentrations of 1,000 organisms per ml, and none was in the 10,000 organisms-per-ml category, and so health-threatening levels of legionella spp. in potable water were significantly lower than in dental-unit water, L. pneumophila was found in 2% of the potable water samples, but only at the lowest detectable level. The results demonstrate that high concentrations of legionella spp. frequently develop in dental-unit water lines. They suggest that, although L. pneumophila is not the dominant component in dental-unit water, heavy exposure to species of Legionella should be investigated as a potential health risk for dental personnel and their immunocompromised patients.
引用
收藏
页码:1208 / 1213
页数:6
相关论文
共 33 条
[1]   STUDIES ON DENTAL AEROBIOLOGY .4. BACTERIAL CONTAMINATION OF WATER DELIVERED BY DENTAL UNITS [J].
ABEL, LC ;
MILLER, RL ;
MICIK, RE ;
RYGE, G .
JOURNAL OF DENTAL RESEARCH, 1971, 50 (06) :1567-&
[2]   AEROSOLS CONTAINING LEGIONELLA-PNEUMOPHILA GENERATED BY SHOWER HEADS AND HOT-WATER FAUCETS [J].
BOLLIN, GE ;
PLOUFFE, JF ;
PARA, MF ;
HACKMAN, B .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1985, 50 (05) :1128-1131
[3]  
BORNEFF M, 1986, ZBL HYG UMWELTMED, V183, P130
[4]   OUTBREAK OF LEGIONNAIRES-DISEASE ASSOCIATED WITH A CONTAMINATED AIR-CONDITIONING COOLING-TOWER [J].
DONDERO, TJ ;
RENDTORFF, RC ;
MALLISON, GF ;
WEEKS, RM ;
LEVY, JS ;
WONG, EW ;
SCHAFFNER, W .
NEW ENGLAND JOURNAL OF MEDICINE, 1980, 302 (07) :365-370
[5]   DISEASE DUE TO THE LEGIONELLACEAE (OTHER THAN LEGIONELLA-PNEUMOPHILA) - HISTORICAL, MICROBIOLOGICAL, CLINICAL, AND EPIDEMIOLOGICAL REVIEW [J].
FANG, GD ;
YU, VL ;
VICKERS, RM .
MEDICINE, 1989, 68 (02) :116-132
[6]   ECOLOGICAL DISTRIBUTION OF LEGIONELLA-PNEUMOPHILA [J].
FLIERMANS, CB ;
CHERRY, WB ;
ORRISON, LH ;
SMITH, SJ ;
TISON, DL ;
POPE, DH .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1981, 41 (01) :9-16
[7]  
FOTOS PG, 1985, J DENT RES, V64, P382
[8]   VIABLE LEGIONELLA-PNEUMOPHILA NOT DETECTABLE BY CULTURE ON AGAR MEDIA [J].
HUSSONG, D ;
COLWELL, RR ;
OBRIEN, M ;
WEISS, E ;
PEARSON, AD ;
WEINER, RM ;
BURGE, WD .
BIO-TECHNOLOGY, 1987, 5 (09) :947-950
[9]  
LAMAIRE W, 1990, MMWR-MORBID MORTAL W, V39, P108
[10]  
LUCK PC, 1993, LEGIONELLA, P240