ECHOCARDIOGRAPHIC ANALYSIS OF CARDIAC-FUNCTION DURING HIGH PEEP VENTILATION

被引:34
|
作者
BERGLUND, JE
HALDEN, E
JAKOBSON, S
LANDELIUS, J
机构
[1] UNIV HOSP UPPSALA,DEPT CLIN PHYSIOL,UPPSALA,SWEDEN
[2] UNIV HOSP UPPSALA,DEPT CLIN RES 2,UPPSALA,SWEDEN
关键词
CARDIAC OUTPUT; VENTRICULAR FUNCTION; POSITIVE END-EXPIRATORY PRESSURE; ECHOCARDIOGRAPHY;
D O I
10.1007/BF01704696
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Does positive end-expiratory pressure ventilation (PEEP) deteriorate cardiac contractility? Design: By means of echocardiography nine piglets were studies during ventilation with 0, 15 and 25 cmH2O (PEEP). Recordings were made before and after 500 ml of 6% dextran 70. Measurement and results: Right and left ventricular end-diastolic diameters were plotted against the stroke volume determined by the thermodilution technique. By combining observations made before and after volume expansion during the different ventilation modes, a ventricular function curve was obtained. The slopes of the curves were similar during all three ventilation modes, both on the left and on the right side. Conclusion: This study indicates undisturbed myocardial contractility during PEEP ventilation. We infer that the cardiac output deterioration in the intact animal is caused entirely by impairment of venous return.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 50 条
  • [1] DOPPLER ECHOCARDIOGRAPHIC ASSESSMENT OF FETAL CARDIAC-FUNCTION
    RIZZO, G
    ARDUINI, D
    ROMANINI, C
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1992, 2 (06) : 434 - 445
  • [2] ECHOCARDIOGRAPHIC EVALUATION OF CARDIAC-FUNCTION IN MULTITRANSFUSED NONCHELATED CHILDREN WITH THALASSEMIA
    SINGH, S
    GROVER, A
    MARWAHA, RK
    GAREWAL, G
    PRAKASH, D
    INTERNATIONAL JOURNAL OF PEDIATRIC HEMATOLOGY/ONCOLOGY, 1995, 2 (04): : 317 - 320
  • [3] CARDIAC-FUNCTION IN ANEURYSMAL SUBARACHNOID HEMORRHAGE - A STUDY OF ELECTROCARDIOGRAPHIC AND ECHOCARDIOGRAPHIC ABNORMALITIES
    DAVIES, KR
    GELB, AW
    MANNINEN, PH
    BOUGHNER, DR
    BISNAIRE, D
    BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (01) : 58 - 63
  • [4] CARDIAC-FUNCTION AND DYSFUNCTION IN HYPERTENSION
    FOUAD, FM
    CLEVELAND CLINIC JOURNAL OF MEDICINE, 1994, 61 (05) : 351 - 355
  • [5] CARDIAC-FUNCTION IN FETAL SHEEP DURING 2 WEEKS OF HYPOXEMIA
    KAMITOMO, M
    LONGO, LD
    GILBERT, RD
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (06): : R1778 - R1785
  • [6] Comparison of cardiac output measured with echocardiographic volumes and aortic Doppler methods during mechanical ventilation
    O. Axler
    B. Megarbane
    C. Lentschener
    H. Fernandez
    Intensive Care Medicine, 2003, 29 : 208 - 217
  • [7] Echocardiographic evaluation of pulmonary venous blood flow and cardiac function changes during one-lung ventilation
    Lee, Su Hyun
    Kim, Namo
    Kim, Hyun I. L.
    Oh, Young Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08): : 13099 - 13108
  • [8] Comparison of cardiac output measured with echocardiographic volumes and aortic Doppler methods during mechanical ventilation
    Axler, O
    Megarbane, B
    Lentschener, C
    Fernandez, H
    INTENSIVE CARE MEDICINE, 2003, 29 (02) : 208 - 217
  • [9] Cardiac function and haernodynamics during transition to high-frequency oscillatory ventilation
    David, M
    von Bardeleben, RS
    Weiler, N
    Markstaller, K
    Scholz, A
    Karmrodt, J
    Eberle, B
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (12) : 944 - 952
  • [10] CARDIAC-FUNCTION DURING ORTHOTOPIC LIVER-TRANSPLANTATION WITH VENOVENOUS BYPASS
    CHEEMA, SPS
    HUGHES, A
    WEBSTER, NR
    BELLAMY, MC
    ANAESTHESIA, 1995, 50 (09) : 776 - 778