QUANTITATION AND PHENOTYPING OF T-CELL CLONES BY FLOW-CYTOMETRY

被引:2
|
作者
STEMME, S
KALLBERG, B
机构
[1] Department of Clinical Chemistry, Gothenburg University, Gothenburg
关键词
LYMPHOCYTE-T; CELL CLONING; CELL CULTURE; FLOW CYTOMETRY;
D O I
10.1016/0022-1759(92)90016-M
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In order to efficiently analyze large numbers of T cell clones, a method tor analysis of small cell cultures by flow cytometry was developed. The aim was to assess cloning efficiency, growth rate and phenotype of T cell clones. The reliability of the flow cytometer for quantitation of cell populations was documented by repeated analysis of manually counted cell samples. In the concentration range from 3000 to 195,000 cells/ml, the correlation coefficient between counts obtained by the flow cytometer and manual cell counts was 0.999 and within-assay coefficients of variation were below 4%. Cell cultures containing less than 200 cells were reliably quantified. The technique was applied for analysis of T cell clonings with different mitogens and in the presence of varying amounts of serum. To reduce time and labour, the cultures were analyzed only 10 days after cloning, when the clones contained less than 100,000 cells. The sensitivity of the flow cytometer in the detection of immunolabeled cells made further expansion of cell cultures unnecessary, thus greatly reducing manual labour and experiment turnover time. The commonly used mitogens phytohemagglutinin (PHA) and the antibody OKT3 resulted in comparable cloning efficiencies and clone sizes. Human serum was essential for high cloning efficiency as well as for continued growth, and could not be substituted with an increased amount of fetal calf serum. When cloning with interleukin-2 at 20,000 U/ml, two growing cell types were identified. The majority of the clones contained CD3+, CD4+, or CD8+ T cells. Ten out of 60 cultures however, contained cells with the CD3-16/56+ NK cell phenotype, indicating that the culture conditions stimulated proliferation of two different cell types. The described method can be applied for rational analysis of large numbers of minute cell cultures, in for example evaluation of different cloning conditions and estimation of precursor cell frequencies in limiting dilution analysis. The simultaneous phenotyping allows precursor cell analysis under conditions that stimulate growth of more than one cell type.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 50 条
  • [21] T-cell flow-cytometry crossmatch and long-term renal graft survival
    Rebibou, JM
    Carvalho Bittencourt, M
    Saint-Hillier, Y
    Chabod, J
    Dupont, I
    Bittard, H
    Chalopin, JM
    Hervé, P
    Tiberghien, P
    CLINICAL TRANSPLANTATION, 2004, 18 (05) : 558 - 563
  • [22] DETECTION OF MINIMAL RESIDUAL T-CELL ACUTE LYMPHOBLASTIC-LEUKEMIA BY FLOW-CYTOMETRY
    GORE, SD
    KASTAN, MB
    GOODMAN, SN
    CIVIN, CI
    JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 132 (02) : 275 - 286
  • [23] EARLY DIAGNOSIS OF CUTANEOUS T-CELL LYMPHOMA BY DNA FLOW-CYTOMETRY ON SKIN BIOPSIES
    WANTZIN, GL
    LARSEN, JK
    CHRISTENSEN, IJ
    RALFKIAER, E
    THOMSEN, K
    CANCER, 1984, 54 (07) : 1348 - 1352
  • [24] Multiparameter flow cytometry in the differential diagnosis of aberrant T-cell clones of unclear significance
    Flammiger, Anna
    Bacher, Ulrike
    Christopeit, Maximilian
    Horn, Christiane
    Ruehlmann, Elke
    Kluge, Katrin
    Vettorazzi, Eik
    Bokemeyer, Carsten
    Binder, Mascha
    LEUKEMIA & LYMPHOMA, 2015, 56 (03) : 639 - 644
  • [25] CLONAL STABILITY OF HYBRIDOMA CLONES DETERMINED BY FLOW-CYTOMETRY
    BARTAL, AH
    ANDREEFF, M
    FEIT, C
    HIRSHAUT, Y
    PROCEEDINGS OF THE AMERICAN ASSOCIATION FOR CANCER RESEARCH, 1985, 26 (MAR): : 286 - 286
  • [26] A PROSPECTIVE COMPARISON OF DNA QUANTITATION BY IMAGE AND FLOW-CYTOMETRY
    BAUER, TW
    TUBBS, RR
    EDINGER, MG
    SUIT, PF
    GEPHARDT, GN
    LEVIN, HS
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1990, 93 (03) : 322 - 326
  • [27] QUANTITATION OF HISTOCOMPATIBILITY ANTIGENS ON RAT LYMPHOCYTES BY FLOW-CYTOMETRY
    HANSEN, E
    BLUT, 1982, 44 (03): : 141 - 150
  • [28] T-CELL DIFFERENTIATION IN ATHYMIC NUDE RATS (RNU/RNU) - DEMONSTRATION OF A DISTORTED T-CELL SUBSET STRUCTURE BY FLOW-CYTOMETRY ANALYSIS
    SCHWINZER, R
    HEDRICH, HJ
    WONIGEIT, K
    EUROPEAN JOURNAL OF IMMUNOLOGY, 1989, 19 (10) : 1841 - 1847
  • [29] ANALYSIS OF THE HUMAN T-CELL RECEPTOR V-GAMMA GENE USAGE BY FLOW-CYTOMETRY
    KABELITZ, D
    T-CELL RECEPTOR USE IN HUMAN AUTOIMMUNE DISEASES, 1995, 756 : 103 - 105
  • [30] FLOW-CYTOMETRY AND CELL SORTING
    FULWYLER, MJ
    BLOOD CELLS, 1980, 6 (02): : 173 - 184