The Effects of the Duration of Use on Stiffness of Nickel-Titanium Orthodontic Wires

被引:0
|
作者
Sheibaninia, Ahmad [1 ]
Ghavidel, Parinaz Beikian [2 ]
Mahmoudi, Farhang [3 ]
机构
[1] Islamic Azad Univ, Dent Sch, Dept Orthodont, Tehran Branch,Orthosurg, Tehran, Iran
[2] Islamic Azad Univ, Dent Sch, Dept Endodont, Khorasegan Branch, Esfahan, Iran
[3] Islamic Azad Univ, Dent Sch, Orthodont Postgrad Dept, Tehran Branch, Tehran, Iran
关键词
Stiffness; NiTi; Orthodontic wire; duration of use;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim and Background: The wire's stiffness might be changed over the usage time. The present in vivo study was conducted to investigate the effects of duration intervals on the stiffness of Nickel-Titanium (NiTi) orthodontic wires with different cross-sections to identify the appropriate size of wires. Materials and Method: The present clinical trial study was conducted on patients who were admitted to the Orthodontics Department of Tehran Dental Branch, Islamic Azad University. Totally, 90 samples of NiTi orthodontic wires, 30 samples with different sizes of 0.014, 0.016, and 0.018 inches were purchased. The measurement of the stiffness had been conducted before, after one month, and after two months of the treatment with 10 samples. The samples were taken to Razi Institute to evaluate archwires' stiffness, using a three-point bending test by Instron tester. Statistical analysis was conducted between and within-group differences using one-way ANOVA. Results: The stiffness of the 0.014, 0.016, and 0.018 inch-NiTi wires was insignificantly reduced from 64.0 +/- 0.8, 78.0 +/- 1.0, and 80.0 +/- 0.7 N/mm(2) before being applied to the mouth to 63.0 +/- 3.0, 77.0 +/- 3.0, and 79.0 +/- 4.0 N/mm(2) after one month and 62.0 +/- 2.0, 76.0 +/- 3.0, and 78.0 +/- 3.0 N/mm(2) after two months of being used, respectively (P=0.8, P= 0.8, and P=0.06, respectively). Conclusion: The stiffness of different cross-sections of NiTi wires did not show any significant changes during the 3 mentioned intervals.
引用
收藏
页码:11 / 14
页数:4
相关论文
共 50 条
  • [41] Comparison of Elastic Properties of Nickel-Titanium Orthodontic Archwires
    Sarul, Michal
    Kawala, Beata
    Antoszewska, Joanna
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2013, 22 (02): : 253 - 260
  • [42] In vitro biocompatibility of nickel-titanium esthetic orthodontic archwires
    Rongo, Roberto
    Valletta, Rosa
    Buccia, Rosaria
    Rivieccio, Virginia
    Galeotti, Angela
    Michelotti, Ambrosina
    D'Anto, Vincenzo
    ANGLE ORTHODONTIST, 2016, 86 (05) : 789 - 795
  • [43] Characterization of closed nickel-titanium orthodontic coil springs
    Langeron, T
    Filleul, MP
    Van Humbeeck, J
    JOURNAL DE PHYSIQUE IV, 2001, 11 (PR8): : 565 - 570
  • [44] A comparison of the bending behaviour of nickel-titanium orthodontic archwires
    Lester, KJ
    Mori, T
    Sims, MR
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 937 - 937
  • [45] Effects of recycling on the mechanical properties and the surface topography of nickel-titanium alloy wires
    Lee, SH
    Chung, YI
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1273 - 1273
  • [46] SURFACE-STRUCTURE AND ROUGHNESS OF NICKEL-TITANIUM WIRES
    FRIES, T
    BOURAUEL, C
    DRESCHER, D
    PLIETSCH, R
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 353 (3-4): : 427 - 432
  • [47] EFFECTS OF CLINICAL RECYCLING ON MECHANICAL-PROPERTIES OF NICKEL-TITANIUM ALLOY WIRES
    KAPILA, S
    REICHHOLD, GW
    ANDERSON, RS
    WATANABE, LG
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1991, 100 (05) : 428 - 435
  • [48] Effects of recycling on the mechanical properties and the surface topography of nickel-titanium alloy wires
    Lee, SH
    Chang, YI
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2001, 120 (06) : 654 - 663
  • [49] COMPARISON OF THE ELASTIC PROPERTIES OF NICKEL-TITANIUM AND BETA TITANIUM ARCH WIRES
    KUSY, RP
    GREENBERG, AR
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1982, 82 (03) : 199 - 205
  • [50] X-ray diffraction study of low-temperature phase transformations in nickel-titanium orthodontic wires
    Iijima, M.
    Brantley, W. A.
    Guo, W. H.
    Clark, W. A. T.
    Yuasa, T.
    Mizoguchi, I.
    DENTAL MATERIALS, 2008, 24 (11) : 1454 - 1460