VALIDITY OF THERMAL DILUTION TECHNIQUE FOR MEASUREMENT OF CARDIAC-OUTPUT IN RATS

被引:22
作者
KISSLING, G
ROSS, C
BRANDLE, M
机构
来源
AMERICAN JOURNAL OF PHYSIOLOGY | 1993年 / 265卷 / 03期
关键词
FICKS METHOD; ELECTROMAGNETIC FLOWMETRY; HEAT DIFFUSION;
D O I
10.1152/ajpheart.1993.265.3.H1007
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The validity of the thermal dilution technique for the measurement of cardiac output was verified in experiments on a circulation model and on anesthetized rats under open- and closed-chest conditions. In the circulation model thermal dilution was compared with direct (F(dir)) and electromagnetic (F(elm)) flowmetry. Flow values measured in the circulation model with the thermal dilution (F(th)) technique correspond well with direct flowmetry (F(th) = 0.92 F(dir) + 7.0; r = 0.888) and with electromagnetic flowmetry (F(th) = 0.95 F(elm) + 1.2; r = 0.990). In the anesthetized rat cardiac output was determined with thermal dilution and simultaneously with Fick's method and/or with electromagnetic flowmetry. Fick's method and electromagnetic flowmetry resulted in identical cardiac output values (CO(Fick) = 0.95 CO(elm); r = 0.865), whereas the thermal dilution technique yielded unequivocally higher values. The extent of overestimation is much more pronounced at low cardiac output than at a high output. The study clearly demonstrates that this overestimation is due to heat diffusion, which is obviously of greater significance in small animals than in large animals or humans. Therefore, the thermal dilution technique is not appropriate for the measurement of cardiac output in the rat.
引用
收藏
页码:H1007 / H1013
页数:7
相关论文
共 31 条
[1]   CARDIAC-OUTPUT AND RENAL EXCRETION RATES DURING ACUTE BLOOD-VOLUME EXPANSION IN RATS [J].
ACKERMANN, U .
AMERICAN JOURNAL OF PHYSIOLOGY, 1978, 234 (01) :H21-H27
[2]   CARDIAC-PERFORMANCE IN RATS WITH RENAL-HYPERTENSION [J].
AVERILL, DB ;
FERRARIO, CM ;
TARAZI, RC ;
SEN, S ;
BAJBUS, R .
CIRCULATION RESEARCH, 1976, 38 (04) :280-288
[3]   CARDIAC OUTPUT IN THE RAT AT NORMAL AND AT HIGH ALTITUDES AND ITS RELATIONSHIP TO GAS EMBOLISM [J].
BLOOD, FR ;
SMITH, DL ;
DAMOUR, FE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1950, 163 (02) :268-271
[4]   MEASUREMENT OF CARDIAC OUTPUT BY THERMAL DILUTION IN MAN [J].
BRANTHWAITE, MA ;
BRADLEY, RD .
JOURNAL OF APPLIED PHYSIOLOGY, 1968, 24 (03) :434-+
[5]  
CHAPMAN BJ, 1977, J PHYSIOL-LONDON, V270, pP3
[7]   SYSTEMIC AND REGIONAL HEMODYNAMIC-EFFECTS OF LEUKOTRIENES D-4 AND E-4 IN THE CONSCIOUS RAT [J].
EIMERL, J ;
SIREN, AL ;
FEUERSTEIN, G .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (04) :H700-H709
[8]  
ENGHOFF E, 1970, ACTA SOC MED UPS SCI, V75, P157
[9]   MEASUREMENT OF CARDIAC OUTPUT IN ANAESTHETIZED ANIMALS BY A THERMO-DILUTION METHOD [J].
FEGLER, G .
QUARTERLY JOURNAL OF EXPERIMENTAL PHYSIOLOGY AND COGNATE MEDICAL SCIENCES, 1954, 39 (03) :153-164
[10]   THERMAL DILUTION CURVES IN THE INTACT ANIMAL [J].
GOODYER, AVN ;
HUVOS, A ;
ECKHARDT, WF ;
OSTBERG, RH .
CIRCULATION RESEARCH, 1959, 7 (03) :432-441