RESULTS OF A CCPR INTERCOMPARISON OF SPECTRAL IRRADIANCE MEASUREMENTS BY NATIONAL LABORATORIES

被引:45
作者
WALKER, JH
SAUNDERS, RD
JACKSON, JK
MIELENZ, KD
机构
[1] Natl Inst of Standards and, Technology, Gaithersburg, MD
关键词
CCPR; INTERCOMPARISON; NATIONAL LABORATORIES; RADIOMETRY; SPECTRAL IRRADIANCE; TUNGSTEN-HALOGEN LAMPS;
D O I
10.6028/jres.096.043
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An intercomparison of spectral irradiance measurements by 12 national laboratories has been carried out between 1987 and 1990. The intercomparison was conducted under the auspices of the Comite Consultatif de Photometrie et Radiometrie (CCPR) of the Comite International des Poids et Mesures, and the National Institute of Standards and Technology (NIST) served as the pilot laboratory. The spectral range of the intercomparison was 250 to 2400 nm and the transfer standards used were commercial tungsten-halogen lamps of two types. The world-wide consistency of the results (one standard deviation) was on the order of 1% in the visible spectral region and 2 to 4% in the ultraviolet and infrared portions of the spectrum. The intercomparison revealed no statistically significant differences between spectral-irradiance scales based on blackbody physics and absolute detector radiometry.
引用
收藏
页码:647 / 668
页数:22
相关论文
共 7 条
  • [1] GOODMAN TM, 1987, REPORT DEV TUNGSTEN
  • [2] THE 1990 NIST SCALES OF THERMAL RADIOMETRY
    MIELENZ, KD
    SAUNDERS, RD
    PARR, AC
    HSIA, JJ
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1990, 95 (06) : 621 - 629
  • [3] THE INTERNATIONAL TEMPERATURE SCALE OF 1990 (ITS-90)
    PRESTONTHOMAS, H
    [J]. METROLOGIA, 1990, 27 (01) : 3 - 10
  • [4] INTERNATIONAL INTERCOMPARISON OF SPECTRAL IRRADIANCE SCALES
    SUZUKI, M
    OOBA, N
    [J]. METROLOGIA, 1976, 12 (03) : 123 - 128
  • [5] WALKER JH, 1987, NBS25020 SPEC PUBL
  • [6] 1990, 12TH SESS BIPM SEVR
  • [7] 1986, 11TH SESS BIPM SEVR