PHOSPHORESCENCE DETECTION IN FLOWING SYSTEMS - SELECTIVE DETERMINATION OF ALUMINUM BY FLOW-INJECTION LIQUID ROOM-TEMPERATURE PHOSPHORIMETRY

被引:15
作者
LIU, YM [1 ]
DELACAMPA, MRF [1 ]
GARCIA, MED [1 ]
SANZMEDEL, A [1 ]
机构
[1] UNIV OVIEDO,FAC CHEM,DEPT PHYS & ANALYT CHEM,JULIAN CLAVERIA S-N,E-33006 OVIEDO,SPAIN
关键词
D O I
10.1016/S0003-2670(00)83562-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The concept of the micelle stabilized liquid room-temperature phosphorescence (MS-LRTP) was applied to the determination of a metal (aluminium) in a flowing system. A three-line flow-injection manifold was developed and various parameters were optimized. A linear calibration graph was obtained for 0-4 μg ml-1 aluminium. The limit of detection was 50 ng ml-1 and the relative standard deviations for 0.1 and 1.0 μg ml-1 aluminium were 2.7 and 1.3% respectively. The proposed procedure is fairly selective. More than 20 common ions studied did not interfere with the determination of aluminium or could be masked by appropriate reagents. The flow-injection method proposed was applied without any preliminary separation to the determination of aluminium in simulated synthetic samples in water and in clinical samples of particular importance in the control of aluminium toxicity in renal failure patients. © 1990.
引用
收藏
页码:233 / 238
页数:6
相关论文
共 50 条
[21]   MICELLE-STABILIZED ROOM-TEMPERATURE LIQUID PHOSPHORIMETRY OF METAL-CHELATES AND ITS APPLICATION TO NIOBIUM DETERMINATION [J].
SANZMEDEL, A ;
GARCIA, PLM ;
GARCIA, MED .
ANALYTICAL CHEMISTRY, 1987, 59 (05) :774-778
[22]   SIMULTANEOUS FLOW-INJECTION DETERMINATION OF ALUMINUM AND ZINC USING LED PHOTOMETRIC DETECTION [J].
TROJANOWICZ, M ;
SZPUNARLOBINSKA, J .
ANALYTICA CHIMICA ACTA, 1990, 230 (01) :125-130
[23]   Zinc Sulfate Open Frameworks with Nonconventional Room-Temperature Phosphorescence for Selective Amine Vapor Detection [J].
Miao, Lei ;
Zhang, Bo-Lun ;
Song, Wen-Tao ;
Chen, Jun ;
Shi, Wen-Jing ;
Wang, Rui-Hong ;
Liu, Shuqin ;
Li, Ying-Jia ;
Zhang, Jian-Jun .
INORGANIC CHEMISTRY, 2025,
[24]   A flow-injection system with amperometric detection for selective determination of antioxidants in foodstuffs and drinks [J].
Yashin, A. Ya. .
RUSSIAN JOURNAL OF GENERAL CHEMISTRY, 2008, 78 (12) :2566-2571
[25]   USE OF A FLOWING NITRATE-SELECTIVE MEMBRANE MICROELECTRODE FOR FLOW-INJECTION AND ION CHROMATOGRAPHIC DETERMINATION OF NITRATES [J].
KUTAS, IM ;
RAKHMANKO, EM ;
GONSALES, I ;
TARASEVICH, VN ;
VINARSKII, VA .
JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1991, 46 (11) :1590-1592
[26]   A flow-injection system with amperometric detection for selective determination of antioxidants in foodstuffs and drinks [J].
A. Ya. Yashin .
Russian Journal of General Chemistry, 2008, 78
[27]   SOLID-SURFACE ROOM-TEMPERATURE PHOSPHORESCENCE DETECTION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CAMPIGLIA, AD ;
BERTHOD, A ;
WINEFORDNER, JD .
JOURNAL OF CHROMATOGRAPHY, 1990, 508 (01) :37-49
[28]   ROOM-TEMPERATURE PHOSPHORESCENCE AS A LIQUID-CHROMATOGRAPHIC DETECTION METHOD FOR POLYCHLORINATED NAPHTHALENES AND BIPHENYLS IN COMPLEX MATRICES [J].
DONKERBROEK, JJ ;
GOOIJER, C ;
VELTHORST, NH ;
FREI, RW .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1983, 15 (04) :281-301
[29]   SOLID-SURFACE ROOM-TEMPERATURE PHOSPHORESCENCE OPTOSENSING IN CONTINUOUS-FLOW SYSTEMS - AN APPROACH FOR ULTRATRACE METAL-ION DETERMINATION [J].
GARCIA, RP ;
LIU, YM ;
GARCIA, MED ;
SANZMEDEL, A .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1759-1763
[30]   Determination of ciprofloxacin with a room-temperature phosphorescence flow-through sensor based on lanthanide-sensitized luminescence [J].
Cuenca-Trujillo, Rosa Ma. ;
Ayora-Canada, Ma. Jose ;
Molina-Diaz, Antonio .
1600, AOAC International (85)