AMPEROMETRIC GLYCOLATE SENSORS BASED ON GLYCOLATE OXIDASE AND POLYMERIC ELECTRON-TRANSFER MEDIATORS

被引:48
作者
HALE, PD
INAGAKI, T
LEE, HS
KARAN, HI
OKAMOTO, Y
SKOTHEIM, TA
机构
[1] Materials Science Division, Department of Applied Science, Brookhaven National Laboratory, Upton
关键词
D O I
10.1016/S0003-2670(00)80475-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using experiments involving cyclic voltammetry and stationary potential measurements, it was shown that siloxane polymers with covalently attached ferrocene and 1,1'-dimethylferrocene relays efficiently mediate electron transfer from reduced glycolate oxidase to a conventional carbon-paste electrode. Sensors containing these polymeric relay systems and glycolate oxidase respond rapidly to low (< 0.1 mM) glycolate concentrations, with steady-state current responses achieved in less than 1 min. The dependence of the sensor response on the nature of the siloxane polymer backbone, the type of polymer-bound redox mediator used and the amount of redox mediator present is discussed. From these considerations, sensors have been designed which can operate efficiently at low applied potential and can avoid decreased current response due to dissolved oxygen. © 1990.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 14 条
[1]   AMPEROMETRIC ENZYME ELECTRODES .2. CONDUCTING SALTS AS ELECTRODE MATERIALS FOR THE OXIDATION OF GLUCOSE-OXIDASE [J].
ALBERY, WJ ;
BARTLETT, PN ;
CRASTON, DH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02) :223-235
[2]  
BARMAN TF, 1969, ENZYME HDB, V1, P101
[3]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[4]   DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .2. METHODS FOR BONDING ELECTRON-TRANSFER RELAYS TO GLUCOSE-OXIDASE AND D-AMINO-ACID OXIDASE [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (08) :2615-2620
[5]   DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .1. ELECTRON-TRANSFER FROM GLUCOSE-OXIDASE TO METAL-ELECTRODES VIA ELECTRON RELAYS, BOUND COVALENTLY TO THE ENZYME [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (06) :1285-1289
[6]   MEDIATED AMPEROMETRIC BIOSENSORS FOR D-GALACTOSE, GLYCOLATE AND L-AMINO-ACIDS BASED ON A FERROCENE-MODIFIED CARBON PASTE ELECTRODE [J].
DICKS, JM ;
ASTON, WJ ;
DAVIS, G ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1986, 182 :103-112
[7]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478
[8]   ENZYME-MODIFIED TETRATHIAFULVALENE TETRACYANOQUINODIMETHANE MICROELECTRODES - DIRECT AMPEROMETRIC DETECTION OF ACETYLCHOLINE AND CHOLINE [J].
HALE, PD ;
WIGHTMAN, RM .
MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1988, 160 :269-279
[9]  
HALE PD, 1989, SYNTHETIC MET, V28, P853
[10]  
HALE PD, 1989, J AM CHEM SOC, V111, P2357