IODINE LASER ENERGY PROFILE MEASUREMENTS AT 1.315 MUM BY USING HYPERSENSITIZED PHOTOGRAPHIC PLATES

被引:3
作者
FARCY, JC [1 ]
BEAUPERE, D [1 ]
机构
[1] COMPAGNIE GEN ELECT,CTR RECH,MARCOUSSIS LABS,F-91460 MARCOUSSIS,FRANCE
关键词
IODINE - PHOTOGRAPHIC FILMS AND PLATES;
D O I
10.1063/1.1135171
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
It is demonstrated that type IZ hypersensitized photographic plates can be efficiently used at 1. 315 mu m. This method is used and discussed to characterize a single transverse mode iodine oscillator. Measurements of the beam distribution and divergence have been carried out and the distribution is shown to be near a Gaussian shape with a divergence near the theoretical value.
引用
收藏
页码:975 / 977
页数:3
相关论文
共 6 条
[1]  
BASOV NG, 1974, SOV J QUANTUM ELECTR, V3, P524
[2]   ASTERIX III PULSED HIGH-POWER IODINE LASER [J].
BREDERLOW, G ;
WITTE, KJ ;
FILL, E ;
HOHLA, K ;
VOLK, R .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1976, 12 (02) :152-155
[3]  
GAIDASH VA, 1974, JETP LETT+, V20, P107
[4]  
MANNING J, 1974, AT291 AEC CONTR
[5]   MODIFIED HYPERSENSITIZATION PROCEDURE FOR EASTMAN KODAK I-Z SPECTROSCOPIC PLATES [J].
POPE, TP ;
KIRBY, TB .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1967, 57 (07) :951-&
[6]  
SELWYN EWH, 1950, PHOTOGRAPHY ASTRONOM, P62