RELIABILITY, VALIDITY AND FOLLOW-UP OF THE EEG IN SENILE DEMENTIA - SEQUELAE OF SEQUENTIAL MEASUREMENT

被引:52
作者
HOOIJER, C
JONKER, C
POSTHUMA, J
VISSER, SL
机构
[1] FREE UNIV AMSTERDAM,DEPT CLIN NEUROPHYSIOL,1075 BG AMSTERDAM,NETHERLANDS
[2] PCA VALERIUSKLIN,AMSTERDAM,NETHERLANDS
[3] HOSP DENNENOORD,ZUIDLAREN,NETHERLANDS
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1990年 / 76卷 / 05期
关键词
EEG; Senile dementia; Sequential measurement;
D O I
10.1016/0013-4694(90)90094-Z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In a longitudinal study, slowing of the EEG in SDAT patients and elderly controls is investigated using both visual and power spectral analyses. For this a reliability study in 20 SDAT patients is performed and results for intra-rater, inter-rater and test-retest reliability (in 24 h) are used in the selection of parameters. Next, the diagnostic efficacy of the chosen parameters for SDAT is confirmed in a validity study in 43 SDAT patients, 41 elderly non-organic psychiatric patients and 51 elderly normals. In the longitudinal study 78 of these subjects could be retested after 20 months. The parameters for visual analysis appeared to be superior in actually showing a progress of slowing of the EEG in 20/21 SDAT patients over time. The parameter for power spectral analysis was superior in measuring the more subtle processes in the normal elderly. Results of these studies are used to discuss some problems in the measurement of EEG in SDAT over time. © 1990.
引用
收藏
页码:400 / 412
页数:13
相关论文
共 37 条
[1]   ASSOCIATION BETWEEN QUANTITATIVE MEASURES OF DEMENTIA AND OF SENILE CHANGE IN CEREBRAL GREY MATTER OF ELDERLY SUBJECTS [J].
BLESSED, G ;
TOMLINSON, BE ;
ROTH, M .
BRITISH JOURNAL OF PSYCHIATRY, 1968, 114 (512) :797-+
[2]   A NOTE ON THE RELIABILITY OF ELECTROENCEPHALOGRAPHIC JUDGMENTS [J].
BLUM, RH .
NEUROLOGY, 1954, 4 (02) :143-146
[3]   DIAGNOSTIC EFFICACY OF COMPUTERIZED SPECTRAL VERSUS VISUAL EEG ANALYSIS IN ELDERLY NORMAL, DEMENTED AND DEPRESSED SUBJECTS [J].
BRENNER, RP ;
REYNOLDS, CF ;
ULRICH, RF .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 69 (02) :110-117
[4]  
BRENNER RP, 1986, ELECTROEN CLIN NEURO, V64, P484
[5]   FREQUENCY-ANALYSIS OF THE RESTING AWAKE EEG IN MILD SENILE DEMENTIA OF ALZHEIMER TYPE [J].
COBEN, LA ;
DANZIGER, WL ;
BERG, L .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1983, 55 (04) :372-380
[6]   A LONGITUDINAL EEG STUDY OF MILD SENILE DEMENTIA OF ALZHEIMER TYPE - CHANGES AT 1 YEAR AND AT 2.5 YEARS [J].
COBEN, LA ;
DANZIGER, W ;
STORANDT, M .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 61 (02) :101-112
[7]   SEMI-STRUCTURED CLINICAL INTERVIEW FOR ASSESSMENT OF DIAGNOSIS AND MENTAL STATE IN ELDERLY - GERIATRIC MENTAL STATE SCHEDULE .1. DEVELOPMENT AND RELIABILITY [J].
COPELAND, JRM ;
KELLEHER, MJ ;
KELLETT, JM ;
GOURLAY, AJ ;
GURLAND, BJ ;
FLEISS, JL ;
SHARPE, L .
PSYCHOLOGICAL MEDICINE, 1976, 6 (03) :439-449
[8]  
Dis HV, 1979, ELECTROENCEPHALOGR C, V47, P87
[9]   TEST-RETEST RELIABILITY OF SPECTRAL PARAMETERS OF THE EEG [J].
GASSER, T ;
BACHER, P ;
STEINBERG, H .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 60 (04) :312-319
[10]   SERIAL EEG STUDIES IN PRESENILE DEMENTIA [J].
GORDON, EB .
BRITISH JOURNAL OF PSYCHIATRY, 1968, 114 (511) :779-&