AMBULATORY BLOOD-PRESSURE MEASUREMENT IN TYPE-2 DIABETIC-PATIENTS - METHODOLOGICAL ASPECTS

被引:24
|
作者
HANSEN, KW
SCHMITZ, A
PEDERSEN, MM
机构
[1] Medical Department M, Aarhus Kommunehospital
关键词
TYPE-2; DIABETES; BLOOD PRESSURE; AMBULATORY BLOOD PRESSURE; MEASUREMENT REPRODUCIBILITY;
D O I
10.1111/j.1464-5491.1991.tb01653.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ambulatory blood pressure was measured over 24 h on two occasions in 29 Type 2 diabetic patients age 65 (range 52-74) years, and the reproducibility compared with that of ordinary clinic measurements recorded by Hawskley's random zero sphygmomanometer. The variability of the difference between blood pressure measurements on the two occasions was twice as large for clinic measurement as for ambulatory measurement (2p < 0.01). If applied to clinical trials this would allow a fourfold reduction of patient numbers without losing test power. In the group of patients treated with antihypertensive medication (n = 16) the spontaneous decline in blood pressure after leaving the hospital proved to be most prominent in those patients with the highest clinic blood pressure, a phenomenon with importance for the management of hypertension. The individual difference between clinic measurements and ambulatory day-time measurements from the same day was unpredictable. Ambulatory blood pressure measurement in the outpatient clinic may be a practicable approach for optimizing antihypertensive treatment in Type 2 diabetic patients.
引用
收藏
页码:567 / 572
页数:6
相关论文
共 50 条
  • [1] AMBULATORY BLOOD-PRESSURE MONITORING IN DIABETIC-PATIENTS
    HALIMI, S
    BENHAMOU, PY
    MALLION, JM
    DEGAUDEMARIS, R
    BACHELOT, I
    DIABETES & METABOLISM, 1991, 17 (06): : 538 - 544
  • [2] AMBULATORY BLOOD-PRESSURE IN MICROALBUMINURIC TYPE-1 DIABETIC-PATIENTS
    HANSEN, KW
    CHRISTENSEN, CK
    ANDERSEN, PH
    PEDERSEN, MM
    CHRISTIANSEN, JS
    MOGENSEN, CE
    KIDNEY INTERNATIONAL, 1992, 41 (04) : 847 - 854
  • [3] AMBULATORY BLOOD-PRESSURE AND ABNORMAL ALBUMINURIA IN TYPE-1 DIABETIC-PATIENTS
    HANSEN, KW
    POULSEN, PL
    MOGENSEN, CE
    KIDNEY INTERNATIONAL, 1994, 45 : S134 - S140
  • [4] METHODOLOGICAL ASPECTS OF BLOOD-PRESSURE MEASUREMENT
    SARGIN, KE
    KARDIOLOGIYA, 1985, 25 (12) : 116 - 117
  • [5] DAY-NIGHT BLOOD-PRESSURE VARIATION IN TYPE-2 DIABETIC-PATIENTS WITH ASYMPTOMATIC AUTONOMIC NEUROPATHY
    JERMENDY, G
    FERENCZI, J
    NADAS, J
    HERNANDEZ, E
    DIABETES, 1995, 44 : A224 - A224
  • [6] AMBULATORY BLOOD-PRESSURE (AMBP) MONITORING IN NORMOALBUMINURIC TYPE-1 (IDDME DIABETIC-PATIENTS
    RAPUANO, A
    PENNO, G
    RIZZO, L
    NANNIPIERI, M
    BANDINELLI, S
    PUCCI, L
    BERTACCA, A
    CARICATO, F
    NAVALESI, R
    DIABETOLOGIA, 1995, 38 : A212 - A212
  • [7] BLOOD-PRESSURE MANAGEMENT IN DIABETIC-PATIENTS
    FERREIRA, SRG
    ZANELLA, MT
    FREIRE, MB
    MILAGRES, R
    PLAVINIK, FL
    RIBEIRO, AB
    NEFROLOGIA, 1994, 14 (03): : 267 - 271
  • [8] EARLY DISTURBANCES OF AMBULATORY BLOOD-PRESSURE LOAD IN NORMOTENSIVE TYPE-1 DIABETIC-PATIENTS WITH MICROALBUMINURIA
    BENHAMOU, PY
    HALIMI, S
    DEGAUDEMARIS, R
    BOIZEL, R
    PITIOT, M
    SICHE, JP
    BACHELOT, I
    MALLION, JM
    DIABETES CARE, 1992, 15 (11) : 1614 - 1619
  • [9] TECHNICAL AND METHODOLOGICAL ASPECTS OF AMBULATORY BLOOD-PRESSURE MONITORING SYSTEMS
    ZURMANN, J
    HERZ, 1989, 14 (04) : 205 - 213
  • [10] IMPAIRED NOCTURNAL DECLINE IN ARTERIAL BLOOD-PRESSURE IN TYPE-2 (NON-INSULIN-DEPENDENT) DIABETIC-PATIENTS WITH NEPHROPATHY
    NIELSEN, FS
    ROSSING, P
    GALL, MA
    PARVING, HH
    DIABETOLOGIA, 1992, 35 : A48 - A48