INFRARED-LASER SCLEROSTOMIES

被引:0
作者
OZLER, SA
HILL, RA
ANDREWS, JJ
BAERVELDT, G
BERNS, MW
机构
[1] UNIV CALIF IRVINE,BECKMAN LASER INST & MED CLIN,MED PLAZA BLDG,DEPT SURG,IRVINE,CA 92715
[2] UNIV CALIF IRVINE,BECKMAN LASER INST & MED CLIN,DEPT OPHTHALMOL,IRVINE,CA 92717
[3] UNIV SO CALIF,ESTELLE DOHENY EYE FDN,DEPT OPHTHALMOL,LOS ANGELES,CA 90089
关键词
GLAUCOMA; LASER; SCLEROSTOMY; FILTRATION SURGERY; FIBEROPTIC;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Four solid-state lasers with three fiberoptic delivery systems were used to perform laser sclerostomies in an acute-injury rabbit model and in fresh human globes. The lasers used were continuous-wave neodymium:yttrium aluminum garnet (YAG, 1.06-mu-m) and pulsed holmium:yttrium scandium galliam garnet (YSGG) (2.10-mu-m), erbium:YSGG (2.79-mu-m), and erbium:YAG (2.94-mu-m). Thermal damage to tissue and total laser energy required to produce sclerostomies decreased with increasing wavelength. In human tissue using a 600-mu-m fused silica fiberoptic, maximum thermal damage (greater-than-or-equal-to 100-mu-m) was noted at 1.06-mu-m with a total energy of 21 J at a power density of 2.5 kW/cm2. In addition, focal damage to the iris and ciliary body was noted at this wavelength. The least amount of thermal damage (15-20-mu-m) and lowest total energies needed were found at 2.94-mu-m. A 250-mu-s pulse length and pulse radiant exposures of 3.6 J/cm2 and 14.3 J/cm2 were used for the low hydroxyl-fused silica (500-mu-m) and zirconium fluoride (250-mu-m) fiberoptics, respectively. Although zirconium fluoride fibers have high through-put efficiencies that facilitate study of laser tissue interactions at 2.94-mu-m, problems encountered with fragility and solubility of the bare tip in aqueous media limit its usefulness. A high attenuation rate with the low hydroxyl-fused silica fiber limited its usable length to 35 cm at 2.94-mu-m. Tissue damage during sclerostomy formation was minimized at 2.94-mu-m, reaching a maximum at 1.06-mu-m. Minimizing tissue damage theoretically could decrease subconjunctival scarring and filtration failure. By comparing the neodymium:YAG with the erbium:YAG laser, this hypothesis can be tested in an in vivo model using a minimal number of laboratory animals.
引用
收藏
页码:2498 / 2503
页数:6
相关论文
共 21 条
[1]  
ADDICKS EM, 1983, ARCH OPHTHALMOL-CHIC, V101, P795
[2]  
BALL C, 1989, OPHTHALMOLOGY TIMES, V14, P33
[3]  
BROWN RH, 1987, ARCH OPHTHALMOL-CHIC, V105, P133
[4]  
DAIKUZONO N, 1985, MED INSTRUM, V19, P173
[5]   MEDICAL APPLICATIONS OF LASERS [J].
DEUTSCH, TF .
PHYSICS TODAY, 1988, 41 (10) :56-63
[6]  
HIGGINBOTHAM EJ, 1988, OPHTHALMOLOGY, V95, P385
[7]   ABINTERNO SCLEROSTOMY WITH A HIGH-POWERED ARGON ENDOLASER - CLINICOPATHOLOGIC CORRELATION [J].
JAFFE, GJ ;
MIELER, WF ;
RADIUS, RL ;
KINCAID, MC ;
MASSARO, BM ;
ABRAMS, GW .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (08) :1183-1185
[8]  
KLOCEK P, 1989, INFRARED FIBER OPTIC, P58
[9]  
MACKENZIE AL, 1989, PHYS MED BIOL, V34, P10
[10]  
MARCH WF, 1987, OPHTHALMIC LASER THE, V2, P161