Reference Ranges of Fetal Cerebral Lateral Ventricle Parameters by Ultrasonography

被引:9
作者
Ishola, Aderemi [1 ]
Asaleye, Christianah Mopelola [1 ]
Ayoola, Oluwagbemiga Oluwole [1 ]
Loto, Olabisi Morebise [2 ,3 ,4 ]
Idowu, Bukunmi Michael [1 ]
机构
[1] Obafemi Awolowo Univ, Dept Radiol, Teaching Hosp Complex, Ife, Osun State, Nigeria
[2] Obafemi Awolowo Univ, Dept Obstet, Teaching Hosp Complex, Ife, Osun State, Nigeria
[3] Obafemi Awolowo Univ, Dept Gynecol, Teaching Hosp Complex, Ife, Osun State, Nigeria
[4] Obafemi Awolowo Univ, Dept Perinatol, Teaching Hosp Complex, Ife, Osun State, Nigeria
来源
REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRICIA | 2016年 / 38卷 / 09期
关键词
ultrasonography; fetus; ventricle; ventriculomegaly; reference range;
D O I
10.1055/s-0036-1593410
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objectives This study was done to evaluate the normal fetal cerebral lateral ventricle dimensions with transabdominal ultrasonography. The atrial width (AW), ventricle-to-choroid measurement (V-C), ventricle-to-hemisphere ratio (VHR), and combined anterior horn measurement (CAHM) were taken. Methods This was a cross-sectional study involving 400 normal singleton pregnant subjects whose gestational ages were between 14 and 40 weeks. Transabdominal sonography was performed to obtain the values of the fetal cerebral lateral ventricle (FCLV) parameters. Data were reported as mean +/- standard deviation (SD) for continuous variables. The degrees of correlation between FCLV parameters and the estimated gestational age (EGA) were obtained using Pearson's correlation. Regression equations were used to generate the reference limits for the FCLV measurements. Results The values of AW, V-C measurements and CAHM increased with advancing gestation. The mean values of the AW, V-C and CAHM from 14 to 40 weeks increased from 6.60 +/- 0.94 mm to 9.75 +/- 0.07 mm (R-2 = 0.114), 0.80 +/- 0.00 mm to 1.90 +/- 0.14 mm (R-2 = 0.266), and 6.95 +/- 0.06 mm to 23.07 +/- 4.02 mm (R-2 = 0.692) respectively, while the mean VHR decreased from 61.20 +/- 1.60% to 42.84 +/- 2.91% (R-2 = 0.706) over the same period. Conclusion The AW, V-C, and CAHM increase, while VHR decreases with advancing gestation.
引用
收藏
页码:428 / 435
页数:8
相关论文
共 50 条
  • [1] Reference ranges for laboratory parameters in rabbits
    Hein, J
    Hartmann, K
    TIERARZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2003, 31 (05): : 321 - 328
  • [2] Reference values for the fetal lateral ventricle atrium measurement in the second and third trimesters of pregnancy in a Brazilian population
    Peixoto, Alberto Borges
    Rodrigues da Cunha Caldas, Taciana Mara
    Barbosa, Marcelle Flausino
    Teixeira Romao, Ludimila dos Anjos
    Martins, Wellington P.
    Araujo Junior, Edward
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2016, 29 (14) : 2337 - 2340
  • [3] Reference Ranges of Fetal Cisterna Magna Length and Area Measurements by 3-Dimensional Ultrasonography Using the Multiplanar Mode
    Passos, Ana Paula
    Araujo Junior, Edward
    Bruns, Rafael Frederico
    Machado Nardozza, Luciano Marcondes
    Moron, Antonio Fernandes
    JOURNAL OF CHILD NEUROLOGY, 2015, 30 (02) : 209 - 215
  • [4] Reference Values for Doppler Parameters of the Fetal Anterior Cerebral Artery throughout Gestation
    Benavides-Serralde, J. A.
    Hernandez-Andrade, E.
    Figueroa-Diesel, H.
    Oros, D.
    Feria, L. A.
    Scheier, M.
    Figueras, F.
    Gratacos, E.
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 2010, 69 (01) : 33 - 39
  • [5] Reference ranges for laboratory parameters in Guinea pigs
    Hein, J
    Hartmann, K
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2003, 31 (06): : 383 - 389
  • [6] Fetal Medicine Foundation reference ranges for umbilical artery and middle cerebral artery pulsatility index and cerebroplacental ratio
    Ciobanu, A.
    Wright, A.
    Syngelaki, A.
    Wright, D.
    Akolekar, R.
    Nicolaides, K. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2019, 53 (04) : 465 - 472
  • [7] Fetal venous blood flow pattern reference ranges (2013)
    Journal of Medical Ultrasonics, 2014, 41 : 131 - 135
  • [8] Longitudinal reference ranges for fetal ultrasound biometry in twin pregnancies
    Liao, Adolfo Wenjaw
    Brizot, Maria de Lourdes
    Kang, Helenice Julio
    Assuncao, Renata Almeida
    Zugaib, Marcelo
    CLINICS, 2012, 67 (05) : 451 - 455
  • [10] Ultrasonography role in assessment of the normal parameter of lateral cerebral ventricular atrium in the fetus
    Alsaegh, Nawar
    Alsalihi, Nawrass J.
    ALKhfaji, Hassan Falah
    REVISTA LATINOAMERICANA DE HIPERTENSION, 2021, 16 (04): : 294 - 297