AIRCRAFT MEASUREMENT OF ELECTRIC-FIELD - SELF-CALIBRATION

被引:29
|
作者
WINN, WP
机构
[1] NEW MEXICO INST MIN & TECHNOL, DEPT PHYS, SOCORRO, NM 87801 USA
[2] NEW MEXICO INST MIN & TECHNOL, GEOPHYS RES CTR, SOCORRO, NM 87801 USA
关键词
D O I
10.1029/93JD00165
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The electric field of a thunderstorm is distorted by the metallic surfaces of airplanes and rockets. The amplitude of the local, distorted electric field can be measured at selected locations on th, surface of the vehicle with electric field meters. Measuring the thunderstorm field entails finding the relations between the local fields at the meters and the ambient, undistorted electric field that would exist in the absence of the vehicle. Calibration can be performed in the following steps: (1) Find linear combinations F0, F1, . . ., of local field amplitudes that are independent of the charge on the vehicle. (2) While the ambient electric field is constant in the Earth coordinate system, rotate the vehicle (roll and turn or roll and pitch) and record the local field amplitudes and the roll, pitch, and heading angles. Find the direction of the electric vector and the ratios between all of the calibration coefficients that best fit the linear combinations of local field amplitudes. (3) Find the magnitude of one of the coefficients by comparison with a calibrated instrument; from this magnitude and all of the ratios, find all of the magnitudes. With this method of calibration, finding out how the linear combinations F0, F1, . . ., depend on the ambient electric field does not require a symmetric placement of the electric field meters, nor does it require any knowledge of the locations of the field meters. However, inverting the expressions to find the ambient field components as functions of the F(i) does place constraints on the locations of the field meters. The results of the above calibration can be used only when the signal at each field meter is a linear function of four parameters: the charge on the airplane and the three components of a uniform electric field from distant charge. When there are five or more electric field meters, the presence of nearby charge can be detected because it is possible to find linear combinations of the signals from five field meters whose value is not zero only when there is nearby charge. This paper presents one method of finding the linear combinations.
引用
收藏
页码:7351 / 7365
页数:15
相关论文
共 50 条
  • [21] Self-Calibration Analysis and Measuring Uncertainty Assessment of Electric Field Sensors Based on Rydberg Atom
    Xiao, Dongping
    Shi, Zhuxin
    Yan, Sheng
    Zhang, Huaiqing
    Yu, Chuanxiang
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (17): : 5321 - 5330
  • [22] DISTRIBUTION OF ELECTRIC-FIELD FOR AN ELECTROSTATIC SPRAY CHARGING AIRCRAFT
    CARLTON, JB
    BOUSE, LF
    TRANSACTIONS OF THE ASAE, 1977, 20 (02): : 248 - &
  • [23] SPHERICAL FIELD METER FOR MEASUREMENT OF THE ELECTRIC-FIELD VECTOR
    KAMRA, AK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (10): : 1401 - 1406
  • [24] Calibration of low-frequency electric-field probes
    Kalibracija merilnikov nizkofrekvenčnega električnega polja
    1600, Electrotechnical Society of Slovenia (84):
  • [25] Catadioptric self-calibration
    Kang, SB
    IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, VOL I, 2000, : 201 - 207
  • [26] ELECTRIC-FIELD INDUCED EMISSION AS A DIAGNOSTIC-TOOL FOR MEASUREMENT OF LOCAL ELECTRIC-FIELD STRENGTHS
    DHARAMSI, AN
    SCHOENBACH, KH
    JOURNAL OF APPLIED PHYSICS, 1991, 69 (05) : 2889 - 2895
  • [27] Improving self-calibration
    Ensslin, Torsten A.
    Junklewitz, Henrik
    Winderling, Lars
    Greiner, Maksim
    Selig, Marco
    PHYSICAL REVIEW E, 2014, 90 (04):
  • [28] ANALYTICAL SELF-CALIBRATION
    KENEFICK, JF
    HARP, BF
    GYER, MS
    PHOTOGRAMMETRIC ENGINEERING, 1972, 38 (11): : 1117 - &
  • [29] Ultrasound self-calibration
    Boctor, Emad M.
    Iordachita, Lulian
    Fichtinger, Gabor
    Hager, Gregory D.
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [30] Self-calibration optimization method for laser tracking multilateral measurement
    Li X.
    Lin H.
    Xue Z.
    Yang G.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (02): : 10 - 17