USE OF CARDIOPULMONARY BYPASS, HIGH-DOSE EPINEPHRINE, AND STANDARD-DOSE EPINEPHRINE IN RESUSCITATION FROM POST-COUNTERSHOCK ELECTROMECHANICAL DISSOCIATION

被引:4
作者
DEBEHNKE, DJ
ANGELOS, MG
LEASURE, JE
机构
[1] Department of Emergency Medicine, Wright State University, Dayton, OH
关键词
CARDIOPULMONARY RESUSCITATION; ELECTROMECHANICAL DISSOCIATION; CARDIOPULMONARY BYPASS; EPINEPHRINE;
D O I
10.1016/S0196-0644(05)80644-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To determine the effects of cardiopulmonary bypass with standard-dose epinephrine, high-dose epinephrine, and standard-dose epinephrine on perfusion pressures, myocardial blood flow, and resuscitation from post-countershock electromechanical dissociation. Design: Prospective, controlled laboratory investigation using a canine cardiac arrest model randomized to receive one of three resuscitation therapies. Interventions: After the production of post-countershock electromechanical dissociation, 25 animals received ten minutes of basic CPR and were randomized to receive cardiopulmonary bypass with standard-dose epinephrine, high-dose epinephrine, or standard-dose epinephrine. Measurements and main results: Myocardial blood flow was measured using a colored microsphere technique at baseline, during basic CPR, and after intervention. Immediate and two-hour resuscitation rates were determined for each group. Return of spontaneous circulation was achieved in eight of eight cardiopulmonary bypass with standard-dose epinephrine compared with four of eight high-dose epinephrine and three of eight standard-dose epinephrine animals (P < .04). One animal was resuscitated with CPR alone and was excluded. Survival to two hours was achieved in five of eight cardiopulmonary bypass with standard-dose epinephrine, four of eight high-dose epinephrine, and three of eight standard-dose epinephrine animals (NS). Coronary perfusion pressure increased significantly in the cardiopulmonary bypass with standard-dose epinephrine group when compared with the other groups (cardiopulmonary bypass with standard dose epinephrine, 76 +/- 45 mm Hg; high-dose epinephrine, 24 +/- 12 mm Hg; standard-dose epinephrine, 3 +/- 14 mm Hg; P< .005). Myocardial blood flow was higher in cardiopulmonary bypass with standard-dose epinephrine and high-dose epinephrine animals compared with standard-dose epinephrine animals but did not reach statistical significance. Cardiac output increased during cardiopulmonary bypass with standard-dose epinephrine (P = .001) and standard-dose epinephrine (NS) compared with basic CPR but decreased after epinephrine administration in the high-dose epinephrine group (NS). Conclusion: Resuscitation from electromechanical dissociation was improved with cardiopulmonary bypass and epinephrine compared with high-dose epinephrine or standard-dose epinephrine alone. However, there was no difference in survival between groups. Cardiopulmonary bypass with standard-dose epinephrine resulted in higher cardiac output, coronary perfusion pressure, and a trend toward higher myocardial blood flow. A short period of cardiopulmonary bypass with epinephrine after prolonged post-countershock electromechanical dissociation cardiac arrest can re-establish sufficient circulation to effect successful early resuscitation.
引用
收藏
页码:1051 / 1057
页数:7
相关论文
共 34 条
  • [1] Stueven, Waite, Trojano, Et al., Prehospital cardiac arrest — A critical analysis of factors affecting survival, Resuscitation, 17, pp. 251-259, (1989)
  • [2] Stueven, Prehospital CPR: A review, in perspective, Resuscitation, 17, pp. S71-S77, (1989)
  • [3] Ritter, Wolfe, Goldstein, Et al., The effect of bystander CPR on survival of out-of-hospital cardiac arrest victims, Am Heart J, 110, pp. 932-937, (1985)
  • [4] Eisenberg, Bergner, Hearne, Out-of-hospital cardiac arrest: A review of major studies and a proposed uniform reporting system, Am J Public Health, 70, pp. 236-240, (1980)
  • [5] Vincent, Thijs, Weil, Et al., Clinical and experimental studies on electromechanical dissociation, Circulation, 64, pp. 18-27, (1981)
  • [6] Edgren, Kelsey, Sutton, Et al., The presenting ECG pattern in survivors of cardiac arrest and its relation to the subsequent long-term survival, Acta Anaesthesiol Scand, 33, pp. 265-271, (1989)
  • [7] Sutton-Tyrrell, Abramson, Safar, Et al., Predictors of electromechanical dissociation during cardiac arrest, Annals of Emergency Medicine, 17, pp. 572-575, (1988)
  • [8] Stueven, Troiano, Thompson, Et al., Bystander/first responder CPR: Ten years experience in a paramedic system, Ann Emerg Med, 15, pp. 707-710, (1986)
  • [9] Vanags, Thakur, Stueven, Et al., Interventions in the therapy of electromechanical dissociation, Resuscitation, 17, pp. 163-171, (1989)
  • [10] Charlap, Kahlam, Lichstein, Et al., Electromechanical dissociation: Diagnosis, pathophysiology, and management, Am Heart J, 118, pp. 355-360, (1989)