ANALYSIS OF INTRA OCULAR LENS POWER ESTIMATION IN PATIENTS ADMITTED FOR CATARACT SURGERY

被引:0
作者
Saleem, Muhammad
Khan, Sardar Bahadur
Khattak, Muhammad Alam
Muhammad, Lal
机构
[1] Gomal Med Coll Khan, Bannu Med Coll Bannu, Kohat, Pakistan
[2] Kohat Inst Med Sci Kohat, Kohat, Pakistan
来源
GOMAL JOURNAL OF MEDICAL SCIENCES | 2009年 / 7卷 / 01期
关键词
Keratometric value; Intraocular Lens; Ocular Axial length;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: According to Pakistan National Blindness and Visual Impairment Survey, cataract accounts for 51.5% of blindness and visual impairment in Pakistan. In most of the camp and primary level facilities intra-ocular lenses are implanted without proper estimation. The purpose of this study was to know the common keratometric, axial length values, IOL powers and whether or not it is advisable to implant intraocular lenses without proper pre-operative assessment. Material & Methods: It was a retrospective study conducted at Department of Ophthalmology, DHQ Teaching Hospital, D.I.Khan. Review of estimated power of IOL of 1000 admitted patients was done. Results: Out of 1000 patients, 473(47.3%) were males and 527(52.7%) females. The youngest patient was 10 years while the oldest was 80. Maximum patients presented in 51-60 years age group. Only 25(2.5%) patients were below 20 years. The range of axial length was 19.50-28.0mm. 581(58.1%) patients were having axial length 22-23.50mm. Ten (1.0%) had axial length >= 26mm and 6(0.6%) <20.0mm. The range of estimated IOL power by SRK II formula with 118.0A constant was 10-33D. Maximum patients, 140(14.0%) were having IOL power of 20.50D. 522(52.2%) patients were having IOL power 20-22.0D. Only 26(2.6%) patients had IOL power of <= 15.0D and 56(5.6%) >= 25D. Conclusion: The estimated power of IOL differs from patient to patient with a wide range of 10D to 33D. Therefore assessment of IOL power by proper keratomery and biometry is desirable for good post-operative vision.
引用
收藏
页码:22 / 26
页数:5
相关论文
共 17 条
[1]   Predicting the refractive outcome after cataract surgery:: the comparison of different IOLs and SRK-II v SRK-T [J].
Elder, MJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (06) :620-622
[2]   Cataract - a global perspective: output, outcome and outlay [J].
Foster, A .
EYE, 1999, 13 (3) :449-453
[3]  
HOLLADAY JT, 1986, ARCH OPHTHALMOL-CHIC, V104, P539
[4]   A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS [J].
HOLLADAY, JT ;
PRAGER, TC ;
CHANDLER, TY ;
MUSGROVE, KH ;
LEWIS, JW ;
RUIZ, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :17-24
[5]  
Jadoon MZ, 2006, IOVS, V47, P4755
[6]  
Krimmer JE, 2001, INSIGHT, V26, P939
[7]  
Lesiews KA, 2002, OPHTHALMOLOGICA, V216, P239
[8]  
Limburg H, 1997, INDIAN J OPHTHALMOL, V47, P135
[9]  
Memon M. Saleh, 1992, JPMA (Journal of the Pakistan Medical Association), V42, P196
[10]  
Naz MA, 2004, PAK J OPHTHALMOL, V20, P143