A review on the buffering capacity of earth building materials

被引:57
作者
McGregor, Fionn [1 ]
Heath, Andrew [2 ]
Maskell, Daniel [2 ]
Fabbri, Antonin [1 ]
Morel, Jean-Claude [3 ]
机构
[1] Univ Lyon, ENTPE, CNRS, LGCB LTDS,UMR 5513, Vaulx En Velin, France
[2] Univ Bath, Dept Architecture & Civil Engn, Bath, Avon, England
[3] Coventry Univ, Fac Engn Environm & Comp, Sch Energy Construct & Environm, Coventry, W Midlands, England
关键词
buildings; structures & design; energy conservation; strength & testing of materials;
D O I
10.1680/jcoma.15.00035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Unfired clay building materials are recognised for their ability to regulate indoor humidity levels through their moisture buffering capacity. Research is being conducted on the moisture buffering capacity of a variety of building materials with natural materials, such as clay, and organic materials, such as hemp or straw, presenting a greater potential to regulate indoor humidity than industrial building materials. Due to their high affinity to water, which is usually regarded as detrimental, clay materials present complex hygrothermal coupling phenomena, which are still under investigation. This paper summarises some recent investigations into the dynamic water adsorption process within clay materials in relation to their ability to regulate indoor air humidity levels. First, a review of the experimental methods to characterise this behaviour is provided. A review of experimentally measured results on the material scale using compressed earth block, rammed earth or plaster samples is then provided, followed by some larger and whole building measurements.
引用
收藏
页码:241 / 251
页数:11
相关论文
共 46 条
[31]   Compressive strength and microstructural analysis of unfired clay masonry bricks [J].
Oti, J. E. ;
Kinuthia, J. M. ;
Bai, J. .
ENGINEERING GEOLOGY, 2009, 109 (3-4) :230-240
[32]   Engineering properties of unfired clay masonry bricks [J].
Oti, J. E. ;
Kinuthia, J. M. ;
Bai, J. .
ENGINEERING GEOLOGY, 2009, 107 (3-4) :130-139
[33]  
Padfield T., 1998, THESIS
[34]  
Rode C., 2005, MOISTURE BUFFERING B
[35]   A comparison of the Nordtest and Japanese test methods for the moisture buffering performance of building materials [J].
Roels, Staf ;
Janssen, Hans .
JOURNAL OF BUILDING PHYSICS, 2006, 30 (02) :137-161
[36]  
Schroeder H, 2010, LEHMBAU
[37]  
Soudani L, 2014, P FRENCH SPEAK C INT, P1
[38]  
Soudani L, 2015, ENERGY BUILDINGS
[39]   The development of a mineral based moisture buffering render [J].
Stahl, Thomas ;
Holzer, Michael ;
Vonbank, Roger .
BAUPHYSIK, 2013, 35 (05) :346-355
[40]   Previous experimental studies and field measurements on moisture buffering by indoor surface materials [J].
Svennberg, Kaisa ;
Lengsfeld, Kristin ;
Harderup, Lars-Erik ;
Holm, Andreas .
JOURNAL OF BUILDING PHYSICS, 2007, 30 (03) :261-274