QUALITY ASSURANCE IN VARIOUS RADIATIVE HYPERTHERMIA SYSTEMS APPLYING A PHANTOM WITH LED MATRIX

被引:24
作者
SCHNEIDER, CJ
VANDIJK, JDP
DELEEUW, AAC
WUST, P
BAUMHOER, W
机构
[1] ACAD ZIEKENHUIS,UTRECHT,NETHERLANDS
[2] FREE UNIV BERLIN,KLINIKUM RUDOLF VIRCHOW,BERLIN,GERMANY
[3] UNIV ESSEN GESAMTHSCH KLINIKUM,ESSEN,GERMANY
关键词
HYPERTHERMIA; RADIOFREQUENCY; QUALITY ASSURANCE; PHANTOM MEASUREMENTS;
D O I
10.3109/02656739409022451
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The Amsterdam phantom with LED-matrix is applied as an instrument in testing the performance of four types of radiative deep-body hyperthermia systems, which are in clinical use in Germany and The Netherlands. The devices tested were Essen's BSD-1000, Berlin's BSD-2000, Utrecht's Coaxial TEM applicator and Amsterdam's Four-waveguide-array. Photographs were taken of the matrix of dipoles loaded with light-emitting diodes (LED) to visualize the distribution of the RF power deposition or specific absorption rate (SAR) in the aperture midplane. The utility of the phantom with LED matrix for various types of radiative hyperthermia systems is demonstrated. Within this preliminary study, the influence of important parameters on the SAR-pattern in the aperture midplane was demonstrated. After corrections on the phase relation of the applicators a central focus in the SAR distribution could be realized in all systems and could also be moved in any direction. The patterns of the central focus changed in its absolute values and its proportions depending on the relative relations of phase and amplitude of the lateral applicators with respect to the top and bottom applicator. Frequency dependency was recognized for the central focus of the BSD-1000 as well as for the irradiation pattern of a single applicator for the BSD-2000. In the Coaxial TEM applicator it was demonstrated that the dimension of the open water bolus influenced the absolute value of SAR in the aperture midplane.
引用
收藏
页码:733 / 747
页数:15
相关论文
共 27 条
  • [1] CDRH RF PHANTOM FOR HYPERTHERMIA SYSTEMS EVALUATIONS
    ALLEN, S
    KANTOR, G
    BASSEN, H
    RUGGERA, P
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1988, 4 (01) : 17 - 23
  • [2] DELEEUW AA, 1991, STRAHLENTHER ONKOL, V167, P329
  • [3] SAR DISTRIBUTION OF THE COAXIAL TEM SYSTEM WITH VARIABLE APERTURE WIDTH - MEASUREMENTS AND MODEL COMPUTATIONS
    DELEEUW, AAC
    LAGENDIJK, JJW
    VANDENBERG, PM
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1990, 6 (02) : 445 - 451
  • [4] SPECIFIC ABSORPTION RATE STEERING BY PATIENT POSITIONING IN THE COAXIAL TEM SYSTEM - PHANTOM INVESTIGATION
    DELEEUW, AAC
    MOOIBROEK, J
    LAGENDIJK, JJW
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1991, 7 (04) : 605 - 611
  • [5] DESIGN OF A CLINICAL DEEP-BODY HYPERTHERMIA SYSTEM BASED ON THE COAXIAL TEM APPLICATOR
    DELEEUW, AAC
    LAGENDIJK, JJW
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1987, 3 (05) : 413 - 421
  • [6] RTOG QUALITY ASSURANCE GUIDELINES FOR CLINICAL-TRIALS USING HYPERTHERMIA
    DEWHIRST, MW
    PHILLIPS, TL
    SAMULSKI, TV
    STAUFFER, P
    SHRIVASTAVA, P
    PALIWAL, B
    PAJAK, T
    GILLIM, M
    SAPOZINK, M
    MYERSON, R
    WATERMAN, FM
    SAPARETO, SA
    CORRY, P
    CETAS, TC
    LEEPER, DB
    FESSENDEN, P
    KAPP, D
    OLESON, JR
    EMAMI, B
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05): : 1249 - 1259
  • [7] QUALITY ASSURANCE GUIDELINES FOR ESHO PROTOCOLS
    HAND, JW
    LAGENDIJK, JJW
    ANDERSEN, JB
    BOLOMEY, JC
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1989, 5 (04) : 421 - 428
  • [8] LAGENDIJK JJW, 1990, HYPERTHERMIA B COMAC, V5, P95
  • [9] EVALUATION OF THE SIGMA-60 APPLICATOR FOR REGIONAL HYPERTHERMIA IN TERMS OF SCATTERING PARAMETERS
    LEYBOVICH, LB
    MYERSON, RJ
    EMAMI, B
    STRAUBE, WL
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1991, 7 (06) : 917 - 935
  • [10] COMPARISON OF NUMERICAL-CALCULATIONS WITH PHANTOM EXPERIMENTS AND CLINICAL MEASUREMENTS
    PAULSEN, KD