TOE PRESSURE DETERMINATION BY AUDIOPHOTOPLETHYSMOGRAPHY

被引:12
作者
FRONEK, A
BLAZEK, V
CURRAN, B
机构
[1] VET AFFAIRS MED CTR,DEPT SURG,SAN DIEGO,CA 92161
[2] INST HOCHFREQUENZTECH & QUANTENELEKTRON,AACHEN,GERMANY
关键词
D O I
10.1016/0741-5214(94)90015-9
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The purpose of this study was to evaluate the performance of audio-photoplethysmography as a modality to measure toe pressure without the requirement of a recorder. Method: A portable photoplethysmograph with an audio output was used to determine toe pressures, and the results were compared with those obtained by a commercial photoplethysmograph with a recorder. Results: Thirty-one measurements in control subjects and 62 measurements in patients with arterial occlusive disease were performed. The average toe pressure recorded with oscillography with standard photoplethysmography was 103.5 mm Hg +/- 14.7 SD and 95.9 mm Hg +/- 13.4 SD with audio-photoplethysmography. In the patient group the pressure recorded with a commercial photoplethysmograph was 65.3 mm Hg +/- 34.9 SD compared with 61.6 mm Hg +/- 34.8 SD obtained with audio-photoplethysmography. The difference in both groups was insignificant, and the correlation between both methods was very good. Conclusion: A portable handheld photoplethysmograph equipped with an audio output was used to measure toe pressure in control subjects and in patients with arterial occlusive disease. The results have been compared with the oscillometric method by a standard commercial photoplethysmograph connected to a recorder. The correlation was very good in the control and patient groups, and the difference between both methods was below the level of statistical significance. The fact that no recorder is needed may help in introducing toe pressure measurement into everyday office diagnostic practice.
引用
收藏
页码:267 / 270
页数:4
相关论文
共 18 条
[1]  
BLAZEK V, 1987, PHLEBOL PROKTOL, V18, P91
[2]  
BONE GE, 1981, SURGERY, V89, P569
[3]   DIGITAL SYSTOLIC PRESSURES IN LOWER LIMB IN ARTERIAL DISEASE [J].
CARTER, SA ;
LEZACK, JD .
CIRCULATION, 1971, 43 (06) :905-&
[4]   THE EFFECT OF BODY HEATING AND COOLING ON THE ANKLE AND TOE SYSTOLIC PRESSURES IN ARTERIAL-DISEASE [J].
CARTER, SA ;
TATE, RB .
JOURNAL OF VASCULAR SURGERY, 1992, 16 (02) :148-153
[5]  
CARTER SA, 1993, ROLE PRESSURE MEASUR, P494
[6]   DIAGNOSIS OF ARTERIAL INSUFFICIENCY WITH MEASUREMENT OF BLOOD PRESSURE IN FINGERS AND TOES [J].
GUNDERSEN, J .
ANGIOLOGY, 1971, 22 (04) :191-+
[7]  
HIRAI M, 1981, J VASC SURG, V15, P380
[8]   HEALING OF ULCERS ON THE FEET CORRELATED WITH DISTAL BLOOD-PRESSURE MEASUREMENTS IN OCCLUSIVE ARTERIAL-DISEASE [J].
HOLSTEIN, P ;
LASSEN, NA .
ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (06) :995-1006
[9]   THE DISTAL BLOOD-PRESSURE PREDICTS HEALING OF AMPUTATIONS ON THE FEET [J].
HOLSTEIN, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (02) :227-233
[10]   TOE BLOOD-PRESSURE IN PERIPHERAL ARTERIAL DISEASE - QUANTITATIVE EVALUATION OF OCCLUSIVE PROCESS LOCALIZED MAINLY IN ARTERIES IN LOWER LEG AND FOOT [J].
HOLSTEIN, P ;
SAGER, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1973, 44 (4-5) :564-572