EFFECTS OF INTRAAORTIC BALLOON PUMPING ON CORONARY HEMODYNAMICS AFTER CORONARY ANGIOPLASTY IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION

被引:24
作者
ISHIHARA, M
SATO, H
TATEISHI, H
KAWAGOE, T
MURAOKA, Y
YOSHIMURA, M
机构
[1] Department of Cardiology, Hiroshima City Hospital, Hiroshima
关键词
D O I
10.1016/0002-8703(92)90391-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
It has been reported that intraaortic balloon pumping can prevent reocclusion after coronary angioplasty for acute myocardial infarction. The speculated mechanism has been the production of markedly enhanced diastolic coronary perfusion pressure; however, most studies have reported that intraaortic balloon pumping has little effect on coronary blood flow. To assess the effectiveness of this procedure, we studied 12 patients with acute anterior myocardial infarction who were undergoing coronary angioplasty and intraaortic balloon pumping. After successful angioplasty, coronary blood flow velocity was measured with a coronary Doppler catheter before and during intraaortic balloon pumping. Although mean coronary blood flow velocity was unchanged, intraaortic balloon pumping increased peak coronary blood flow velocity from 34.6 +/- 5.0 cm/sec (mean +/- SEM) to 46.7 +/- 5.8 cm/sec (p < 0.005). Such an increase in peak coronary blood flow velocity seemed to be a mechanism by which intraaortic balloon pumping could prevent reocclusion after coronary angioplasty for acute myocardial infarction.
引用
收藏
页码:1133 / 1138
页数:6
相关论文
共 27 条
[21]  
SERRUYS PW, 1988, AM J CARDIOL, V61, P252
[22]   EFFECTS OF INTRA-AORTIC BALLOON COUNTERPULSATION ON REGIONAL CORONARY BLOOD-FLOW IN EXPERIMENTAL MYOCARDIAL-INFARCTION [J].
SHAW, J ;
TAYLOR, DR ;
PITT, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 34 (05) :552-556
[23]   SUBSELECTIVE MEASUREMENT OF CORONARY BLOOD-FLOW VELOCITY USING A STEERABLE DOPPLER CATHETER [J].
SIBLEY, DH ;
MILLAR, HD ;
HARTLEY, CJ ;
WHITLOW, PL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (06) :1332-1340
[24]  
WILLERSON JT, 1977, AM J MED, V62, P687
[25]   THE EFFECT OF INTRA-AORTIC BALLOON COUNTERPULSATION ON REGIONAL MYOCARDIAL BLOOD-FLOW AND OXYGEN-CONSUMPTION IN THE PRESENCE OF CORONARY-ARTERY STENOSIS IN PATIENTS WITH UNSTABLE ANGINA [J].
WILLIAMS, DO ;
KORR, KS ;
GEWIRTZ, H ;
MOST, AS .
CIRCULATION, 1982, 66 (03) :593-597
[26]   TRANS-LUMINAL, SUBSELECTIVE MEASUREMENT OF CORONARY-ARTERY BLOOD-FLOW VELOCITY AND VASODILATOR RESERVE IN MAN [J].
WILSON, RF ;
LAUGHLIN, DE ;
ACKELL, PH ;
CHILIAN, WM ;
HOLIDA, MD ;
HARTLEY, CJ ;
ARMSTRONG, ML ;
MARCUS, ML ;
WHITE, CW .
CIRCULATION, 1985, 72 (01) :82-92
[27]  
YELLIN EL, 1966, CIRC RES, V21, P791