Changes of center of rotation and femoral offset in total hip arthroplasty

被引:41
作者
Bjarnason, Jon A. [1 ]
Reikeras, Olav [1 ]
机构
[1] Oslo Univ Hosp, Rikshosp, Dept Orthoped, Sognsvannsveien 27, N-0027 Oslo, Norway
关键词
Acetabular offset; center of rotation (COR); femoral offset; global offset; total hip arthroplasty (THA);
D O I
10.3978/j.issn.2305-5839.2015.12.37
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: It is a challenge to reconstruct the center of rotation (COR) and femoroacetabular offset anatomically in total hip arthroplasty (THA). We addressed the controversy how we manage to preserve the COR and femoroacetabular offset with an uncemented total hip prosthesis implanted with free hand technique. Methods: We analyzed a prospective series of 73 patients who underwent primary THA. The series was composed of 40 females and 33 males, mean age 64 years (range, 35-90 years). The reasons for THA were primary osteoarthritis (n=63) and developmental dysplasia of the hip (n=10). Pre- and postoperative X-rays were done in a standardized format for anterior-posterior (AP) radiographs of the pelvis, and digitalized measurements were done using SectraTM. We compared preoperative measurements with the final outcome to determine changes in COR and femoral offset. Results: We found that 40 patients had their COR and 34 patients had their femoral offset preserved within preoperative 5.0 mm limits. Twenty-three patients had both their values of COR and femoral offset preserved within 5.0 mm limits. While a significant correlation was found between changes of femoral and global offset (r=0.786, P<0.001), there were no correlation between changes of acetabular and femoral offset (r=-0.027, P=0.822). Conclusions: Using an uncemented THA and free hand technique, there is a fair reproducibility of anatomy. The variations were mostly minor, but our results indicate a potential for better restoring the location of COR and femoral offset when planning and implanting an uncemented THA.
引用
收藏
页数:7
相关论文
共 31 条
[21]   Precision of Robotic Guided Instrumentation for Acetabular Component Positioning [J].
Kanawade, Vaibhav ;
Dorr, Lawrence D. ;
Banks, Scott A. ;
Zhang, Zenan ;
Wan, Zhinian .
JOURNAL OF ARTHROPLASTY, 2015, 30 (03) :392-397
[22]   Common misconceptions of normal hip joint relations on pelvic radiographs [J].
Krishnan, SP ;
Carrington, RWJ ;
Mohiyaddin, S ;
Garlick, N .
JOURNAL OF ARTHROPLASTY, 2006, 21 (03) :409-412
[23]   Femoral offset: Anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty [J].
Lecerf, G. ;
Fessy, M. H. ;
Philippot, R. ;
Massin, P. ;
Giraud, F. ;
Flecher, X. ;
Girard, J. ;
Mertl, P. ;
Marchetti, E. ;
Stindel, E. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (03) :210-219
[24]   The influence of femoral offset on health-related quality of life after total hip replacement [J].
Liebs, T. R. ;
Nasser, L. ;
Herzberg, W. ;
Ruether, W. ;
Hassenpflug, J. .
BONE & JOINT JOURNAL, 2014, 96B (01) :36-42
[25]  
Ramaniraka NA, 2000, REV CHIR ORTHOP, V86, P590
[26]   Effect of pelvic tilt on acetabular retroversion: A study of pelves from cadavers [J].
Siebenrock, KA ;
Kalbermatten, DF ;
Ganz, R .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (407) :241-248
[27]   Benefit of Cup Medialization in Total Hip Arthroplasty is Associated With Femoral Anatomy [J].
Terrier, Alexandre ;
Florencio, Francesc Levrero ;
Ruediger, Hannes A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (10) :3159-3165
[28]   Fixation method does not affect restoration of rotation center in hip replacements: A single-site retrospective study [J].
Wegner, Alexander ;
Kauther, Max Daniel ;
Landgraeber, Stefan ;
von Knoch, Marius .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2012, 7
[29]   Results of a method of leg-length equalization for patients undergoing primary total hip replacement [J].
Woolson, ST ;
Hartford, JM ;
Sawyer, A .
JOURNAL OF ARTHROPLASTY, 1999, 14 (02) :159-164
[30]  
Yamaguchi T, 2004, J Orthop Surg (Hong Kong), V12, P164