摘要
Measurements of bremsstrahlung down to 7 keV emitted from a 7.25 GHz electron cyclotron resonance discharge and the deconvolution of the spectra using a newly developed integration method yield the exact electron distribution function. Two separate electron populations with temperatures about 3 and 25 keV and with densities about (0.2⋯4)108 cm-3 were recorded. First, results are obtained for the behavior of these populations belonging to the mixture (argon-oxygen-hydrogen). Gas mixing increases the densities of these populations, but hardly changes the temperatures. © 1995 American Institute of Physics.
引用
收藏
页码:2138 / 2140
页数:3
相关论文
共 15 条
[1]   THE POLARIZATION OF BREMSSTRAHLUNG X-RAYS EMITTED FROM AN ECR PLASMA [J].
ABE, N ;
YAMAMOTO, T ;
KAWANISHI, M .
JAPANESE JOURNAL OF APPLIED PHYSICS, 1980, 19 (06) :1147-1151
[2]   HOT-ELECTRON STUDIES IN THE MINIMAFIOS ECR ION-SOURCE [J].
BARUE, C ;
BRIAND, P ;
GIRARD, A ;
MELIN, G ;
BRIFFOD, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04) :2844-2846
[4]   X-RAY BREMSSTRAHLUNG MEASUREMENTS ON AN ECR-DISCHARGE IN A MAGNETIC-MIRROR [J].
BERNHARDI, K ;
WIESEMANN, K .
PLASMA PHYSICS AND CONTROLLED FUSION, 1982, 24 (08) :867-884
[5]   THE ECR ION-SOURCE AND ASSOCIATED EQUIPMENT AT THE KVI [J].
DRENTJE, AG .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1985, 9 (04) :526-528
[6]   ANGLE DISPERSIVE DE-CONVOLUTION OF BREMSSTRAHLUNG SPECTRA FROM PLASMA [J].
FRIEDLEIN, R ;
ZSCHORNACK, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (2-3) :554-557
[7]  
GARDNER RC, 1987, PHYS REV LETT, V59, P1821
[8]  
GELLER R, 1990, ANNU REV NUCL PART S, V40, P15
[9]   PLASMA DIAGNOSIS RELATED TO ION SOURCES [J].
GIRARD, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04) :2676-2682
[10]  
GIRARD A, 1993, COMMUNICATI0N