SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY OF LEAD AND CADMIUM AT CYLINDRICAL GRAPHITE FIBER MICROELECTRODES WITH INSITU PLATED MERCURY FILMS

被引:30
|
作者
WOJCIECHOWSKI, M
BALCERZAK, J
机构
[1] Department of Chemistry and Biochemistry, University of Maryland, Baltimore, MD 21228, Baltimore County Campus
关键词
ANODIC STRIPPING VOLTAMMETRY; CADMIUM; LEAD;
D O I
10.1016/S0003-2670(00)83017-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Square-wave anodic stripping voltammetry (SWASV) at a cylindrical, 8-mu-m graphite fiber microelectrode with an in situ plated thin mercury film was investigated in oxygen-free and air-saturated solutions containing high and low concentrations of a supporting electrolyte. Owing to the non-planar (cylindrical) diffusion-enhanced mass transport at the microelectrode surface, very high steady-state current densities were observed at the microelectrode, e.g. 1.2 mA l mmol-1 cm-2 for a -1.0 V reduction of 0.59 mM Hg(II) in 0.1 M acetate buffer. To obtain such high current densities at a conventional rotating disk electrode (RDE), the RDE must be rotated at 1600 rpm. Because of the high speed and background rejection features of square-wave voltammetry, SWASV measurements (without background subtraction) of lead and cadmium at the in situ mercury-plated microelectrodes are not affected by the presence of dissolved oxygen, despite a high yield of oxygen diffusion to the microelectrode. Enhanced SWASV peaks were recorded for lead and cadmium in millimolar solutions of supporting electrolytes. In a non-deaerated and quiescent solution of 0.84 mM acetate buffer, for example, the method yielded a detection limit of 5 x 10(-10) M for each metal. This represents a very impressive sensitivity of the method, especially when one considers the very small dimensions of the microelectrode, the absence of solution stirring and purging and the relatively short deposition time used (2 min). In addition to improved sensitivity, SWASV at in situ mercury-plated microelectrodes offers other advantages over the commonly used anodic stripping methods such as differential-pulse anodic stripping voltammetry, particularly in terms of speed, convenience and applicability. Because of the elimination of both the oxygen removal step and solution stirring, and because of the use of the very fast stripping technique, the method is significantly faster and technically simpler, and thus more convenient for analysis. Also, because of the incorporation of cylindrical microelectrodes, the method does not require high concentrations of supporting electrolytes or sophisticated instrumentation, and can be applied for the analysis of microvolume samples.
引用
收藏
页码:433 / 445
页数:13
相关论文
共 50 条
  • [41] Electrochemical determination of Cd2+ at a titanium electrode modified with a lead film by square wave anodic stripping voltammetry
    Smaili, Fatiha
    Benchettara, Abdelkader
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2016, 52 (01) : 27 - 36
  • [42] Electrodeposition of zinc hydroxide on carbon graphite electrode for electrochemical determination of trace copper in water samples using square wave anodic stripping voltammetry
    Berrabah, Salah Eddine
    Benchettara, Abdelkader
    Smaili, Fatiha
    Tabti, Sabrina
    Benchettara, Abdelhakim
    MATERIALS CHEMISTRY AND PHYSICS, 2022, 278
  • [43] MODIFIED GRAPHITE/GRAPHENE DOT MICROSENSORS FOR THE ASSAY OF TRACE AMOUNTS OF LEAD AND CADMIUM IN WATER CATCHMENTS AREAS USING DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY
    Van Staden, Jacobus Frederick
    Arnold Tatu, Georgiana-Luiza
    REVUE ROUMAINE DE CHIMIE, 2019, 64 (10) : 867 - 877
  • [44] Square wave anodic stripping voltammetry determination of lead based on the Hg(II) immobilized graphene oxide composite film as an enhanced sensing platform
    Zhao, Qiang
    Chai, Yaqin
    Yuan, Ruo
    Luo, Junhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 379 - 384
  • [45] Square wave anodic stripping voltammetric analysis of lead and cadmium utilizing titanium dioxide/zirconium dioxide carbon paste composite electrode
    Phuong Khanh Quoc Nguyen
    Lunsford, Suzanne K.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 711 : 45 - 52
  • [46] Functionalized nanoporous track-etched β-PVDF membrane electrodes for lead(II) determination by square wave anodic stripping voltammetry
    Bessbousse, Haad
    Nandhakumar, Iris
    Decker, Maxime
    Barsbay, Murat
    Cuscito, Olivia
    Lairez, Didier
    Clochard, Marie-Claude
    Wade, Travis. L.
    ANALYTICAL METHODS, 2011, 3 (06) : 1351 - 1359
  • [47] Kinetic and equilibrium studies for the adsorption process of cadmium(II) and copper(II) onto Pseudomonas aeruginosa using square wave anodic stripping voltammetry method
    Kong, Bo
    Tang, Biyu
    Liu, Xiaoying
    Zeng, Xiandong
    Duan, Haiyan
    Luo, Shenglian
    Wei, Wanzhi
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) : 455 - 460
  • [48] Carbon Paste Electrode Modified with Organofunctionalized Mesoporous Silica for Electrochemical Detection and Quantitative Determination of Cadmium (II) Using Square Wave Anodic Stripping Voltammetry
    Popa, Dana Elena
    Buleandra, Mihaela
    Mureseanu, Mihaela
    Ionica, Marcel
    Tanase, Ion Gh.
    REVISTA DE CHIMIE, 2010, 61 (02): : 162 - 167
  • [49] Determination of Pb2+ ions by square-wave anodic stripping voltammetry using silver nanoparticles grown on indium tin oxide substrate
    Bin Huang, Rong
    Zheng, Yi Fan
    MICRO & NANO LETTERS, 2014, 9 (11): : 766 - 769
  • [50] Pseudo-stir bar hollow fiber solid/liquid phase microextraction combined with anodic stripping voltammetry for determination of lead and cadmium in water samples
    Es'haghi, Zarrin
    Hoseini, Hasan Ali
    Mohammadi-Nokhandani, Saeed
    Ebrahimi, Javad