SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY OF LEAD AND CADMIUM AT CYLINDRICAL GRAPHITE FIBER MICROELECTRODES WITH INSITU PLATED MERCURY FILMS

被引:30
|
作者
WOJCIECHOWSKI, M
BALCERZAK, J
机构
[1] Department of Chemistry and Biochemistry, University of Maryland, Baltimore, MD 21228, Baltimore County Campus
关键词
ANODIC STRIPPING VOLTAMMETRY; CADMIUM; LEAD;
D O I
10.1016/S0003-2670(00)83017-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Square-wave anodic stripping voltammetry (SWASV) at a cylindrical, 8-mu-m graphite fiber microelectrode with an in situ plated thin mercury film was investigated in oxygen-free and air-saturated solutions containing high and low concentrations of a supporting electrolyte. Owing to the non-planar (cylindrical) diffusion-enhanced mass transport at the microelectrode surface, very high steady-state current densities were observed at the microelectrode, e.g. 1.2 mA l mmol-1 cm-2 for a -1.0 V reduction of 0.59 mM Hg(II) in 0.1 M acetate buffer. To obtain such high current densities at a conventional rotating disk electrode (RDE), the RDE must be rotated at 1600 rpm. Because of the high speed and background rejection features of square-wave voltammetry, SWASV measurements (without background subtraction) of lead and cadmium at the in situ mercury-plated microelectrodes are not affected by the presence of dissolved oxygen, despite a high yield of oxygen diffusion to the microelectrode. Enhanced SWASV peaks were recorded for lead and cadmium in millimolar solutions of supporting electrolytes. In a non-deaerated and quiescent solution of 0.84 mM acetate buffer, for example, the method yielded a detection limit of 5 x 10(-10) M for each metal. This represents a very impressive sensitivity of the method, especially when one considers the very small dimensions of the microelectrode, the absence of solution stirring and purging and the relatively short deposition time used (2 min). In addition to improved sensitivity, SWASV at in situ mercury-plated microelectrodes offers other advantages over the commonly used anodic stripping methods such as differential-pulse anodic stripping voltammetry, particularly in terms of speed, convenience and applicability. Because of the elimination of both the oxygen removal step and solution stirring, and because of the use of the very fast stripping technique, the method is significantly faster and technically simpler, and thus more convenient for analysis. Also, because of the incorporation of cylindrical microelectrodes, the method does not require high concentrations of supporting electrolytes or sophisticated instrumentation, and can be applied for the analysis of microvolume samples.
引用
收藏
页码:433 / 445
页数:13
相关论文
共 50 条
  • [1] Quantification of lead and cadmium in poultry and bird game meat by square-wave anodic-stripping voltammetry
    Trevisani, M.
    Cecchini, M.
    Taffetani, L.
    Vercellotti, L.
    Rosmini, R.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (02): : 180 - 188
  • [2] SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY IN STATIONARY AND FLOWING SOLUTION - A COMPARATIVE-STUDY
    BRETT, CMA
    LIMA, JLFC
    GARCIA, MBQ
    ANALYST, 1994, 119 (06) : 1229 - 1233
  • [3] Kinetic speciation of lead and cadmium in freshwaters using square-wave anodic stripping voltammetry with a thin mercury film rotating disk electrode
    Lam, MT
    Murimboh, J
    Hassan, NM
    Chakrabarti, CL
    ELECTROANALYSIS, 2001, 13 (02) : 94 - 99
  • [4] IN-FLOW SPECIATION OF COPPER, ZINC, LEAD AND CADMIUM IN FRESH-WATERS BY SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY .2. OPTIMIZATION OF MEASUREMENT STEP
    MARTINOTTI, W
    QUEIRAZZA, G
    GUARINONI, A
    MORI, G
    ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 183 - 191
  • [5] Cadmium and lead complexation by anodic stripping voltammetry with a mercury microelectrode
    dosSantos, MMC
    Goncalves, MLS
    Capelo, S
    ELECTROANALYSIS, 1996, 8 (02) : 178 - 182
  • [6] Determination of nanomolar concentrations of lead and cadmium by anodic-stripping voltammetry at the silver electrode
    Bonfil, Y
    Kirowa-Eisner, E
    ANALYTICA CHIMICA ACTA, 2002, 457 (02) : 285 - 296
  • [7] ANODIC-STRIPPING VOLTAMMETRY OF LEAD USING A COPPER-MERCURY FILM ELECTRODE
    GUNASINGHAM, H
    DALANGIN, RR
    ANALYTICA CHIMICA ACTA, 1991, 246 (02) : 309 - 313
  • [8] Simultaneous determination of cadmium, lead and copper in chocolate samples by square wave anodic stripping voltammetry
    Silva, Larissa Pinto
    Campos, Naira Da Silva
    Lisboa, Thalles Pedrosa
    de Faria, Lucas Vinicius
    Matos, Maria Auxiliadora Costa
    Matos, Renato Camargo
    de Sousa, Rafael Arromba
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (03): : 418 - 426
  • [9] Simultaneous determination of cadmium (II), lead (II), copper (II) and mercury (II) by square-wave anodic stripping voltammetry at a montmorillonite-calcium modified carbon paste electrode
    Beltagi, Amr M.
    Ghoneim, Enass M.
    Ghoneim, Mohamed M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (01) : 17 - 32
  • [10] Anodic stripping voltammetry of lead and cadmium using a mercury film electrode and thiocyanate
    Fischer, E
    van den Berg, CMG