GLOMUS TUMORS OF THE SKULL BASE - COMBINED USE OF MR-ANGIOGRAPHY AND SPIN-ECHO IMAGING

被引:50
|
作者
VOGL, TJ
JUERGENS, M
BALZER, JO
MACK, MG
BERGMAN, C
GREVERS, G
LISSNER, J
FELIX, R
机构
[1] UNIV MUNICH,DEPT RADIOL,MUNICH,GERMANY
[2] UNIV MUNICH,DEPT HEAD & NECK SURG,MUNICH,GERMANY
关键词
CEREBRAL ANGIOGRAPHY; CEREBRAL BLOOD VESSELS; THROMBOSIS; EAR; NEOPLASMS; PARAGANGLIOMA; MAGNETIC RESONANCE (MR); VASCULAR STUDIES; SKULL; BASE;
D O I
10.1148/radiology.192.1.8208919
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the use of magnetic resonance (MR) angiography in the diagnosis of glomus tumors of the skull base. MATERIALS AND METHODS: In 40 patients with pulsatile tinnitus, spin-echo (SE) images, single sections, and maximum intensity projections from gradient-echo sequences,including arterial MR angiography and MR venography, were evaluated for tumor detection. Interpretations by two independent observers were correlated with findings from histologic examination, digital subtraction angiography, computed tomography, and clinical follow-up. RESULTS: Glomus tumors were detected near the tympanic plexus (n = 8) and close to the superior (n = 8) and inferior (n = 1) ganglia of the vagus nerve. Sixteen of 18 proved tumors were detected with SE images alone. Although four high-lying jugular bulbs were misinterpreted as tumor due to similar signal intensity, combined evaluation allowed differentiation between tumor and sinusal blood flow in all cases. CONCLUSION: The authors recommend combined SE imaging and MR angiography for ruling out tumor in patients with pulsatile tinnitus.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
  • [41] LEFT-VENTRICULAR MEASUREMENTS WITH CINE AND SPIN-ECHO MR IMAGING - A STUDY OF REPRODUCIBILITY WITH VARIANCE COMPONENT ANALYSIS
    PATTYNAMA, PMT
    LAMB, HJ
    VANDERVELDE, EA
    VANDERWALL, EE
    DEROOS, A
    RADIOLOGY, 1993, 187 (01) : 261 - 268
  • [42] Meniscal tears of the knee: Accuracy of detection with fast spin-echo MR imaging and arthroscopic correlation in 293 patients
    Cheung, LP
    Li, KCP
    Hollett, MD
    Bergman, AG
    Herfkens, RJ
    RADIOLOGY, 1997, 203 (02) : 508 - 512
  • [43] CARDIAC ABNORMALITIES - ASSESSMENT WITH T2-WEIGHTED TURBO SPIN-ECHO MR-IMAGING WITH ELECTROCARDIOGRAM GATING AT 0.5 T
    SEELOS, KC
    VONSMEKAL, A
    VAHLENSIECK, M
    GIESEKE, J
    REISER, M
    RADIOLOGY, 1993, 189 (02) : 517 - 522
  • [44] ADRENAL MASSES IN PATIENTS WITH MALIGNANCY - PROSPECTIVE COMPARISON OF ECHO-PLANAR, FAST SPIN-ECHO, AND CHEMICAL-SHIFT MR-IMAGING
    SCHWARTZ, LH
    PANICEK, DM
    KOUTCHER, JA
    BROWN, KT
    GETRAJDMAN, GI
    HEELAN, RT
    BURT, M
    RADIOLOGY, 1995, 197 (02) : 421 - 425
  • [45] Peripheral MR angiography: Separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo imaging
    Miyazaki, M
    Takai, H
    Sugiura, S
    Wada, H
    Kuwahara, R
    Urata, L
    RADIOLOGY, 2003, 227 (03) : 890 - 896
  • [46] Mesial temporal sclerosis: Diagnosis with fluid-attenuated inversion-recovery versus spin-echo MR imaging
    Jack, CR
    Rydberg, CH
    Krecke, KN
    Trenerry, MR
    Parisi, JE
    Rydberg, JN
    Cascino, GD
    Riederer, SJ
    RADIOLOGY, 1996, 199 (02) : 367 - 373
  • [47] THE HIPPOCAMPUS IN STATUS EPILEPTICUS - DEMONSTRATION OF SIGNAL INTENSITY AND MORPHOLOGIC CHANGES WITH SEQUENTIAL FAST SPIN-ECHO MR-IMAGING
    TIEN, RD
    FELSBERG, GJ
    RADIOLOGY, 1995, 194 (01) : 249 - 256
  • [48] T2-weighted MR imaging for focal hepatic lesion detection: Supplementary value of breath-hold imaging with half-Fourier single-shot fast spin-echo and multishot spin-echo echoplanar sequences
    Matsuo, M
    Kanematsu, M
    Murakami, T
    Kim, T
    Hori, M
    Kondo, H
    Nakamura, H
    Hoshi, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (03) : 444 - 452
  • [49] BONE CONTUSIONS OF THE KNEE - INCREASED LESION DETECTION WITH FAST SPIN-ECHO MR-IMAGING WITH SPECTROSCOPIC FAT-SATURATION
    KAPELOV, SR
    TERESI, LM
    BRADLEY, WG
    BUCCIARELLI, NR
    MURAKAMI, DM
    MULLIN, WJ
    JORDAN, JE
    RADIOLOGY, 1993, 189 (03) : 901 - 904
  • [50] Cervical spine: Three-dimensional fast spin-echo MR imaging - Improved recovery of longitudinal magnetization with driven equilibrium pulse
    Melhem, ER