RELATION BETWEEN MYOCARDIAL UPTAKE OF TL-201 CHLORIDE AND F-18 FLUORODEOXYGLUCOSE IMAGED WITH SINGLE-PHOTON EMISSION TOMOGRAPHY IN NORMAL INDIVIDUALS

被引:20
作者
BAX, JJ
VISSER, FC
VANLINGEN, A
GROENEVELD, ABJ
HUITINK, JM
TEULE, GJJ
VISSER, CA
机构
[1] FREE UNIV AMSTERDAM HOSP,DEPT INTERNAL MED,1081 HV AMSTERDAM,NETHERLANDS
[2] FREE UNIV AMSTERDAM HOSP,DEPT NUCL MED,1081 HV AMSTERDAM,NETHERLANDS
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1995年 / 22卷 / 01期
关键词
F-18; FLUORODEOXYGLUCOSE; THALLIUM; 201; CHLORIDE; SINGLE-PHOTON EMISSION TOMOGRAPHY; NORMAL INDIVIDUALS;
D O I
10.1007/BF00997248
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, we have demonstrated the feasibility of imaging myocardial uptake of fluorine-18 fluorodeoxyglucose (FDG) with single-photon emission tomography (SPET) using a specially designed collimator, Thallium-201 was used to determine distribution of perfusion for comparison with FDG uptake. However, regional Tl-201 and FDG activities may be different, based on differences in tracer attenuation and the use of different collimators. To study the relation between tracer activities imaged with SPET, nine healthy individuals underwent resting Tl-201 SPET and FDG SPET during a hyperinsulinaemic euglycaemic clamp. The SPET data were analysed semiquantitatively, using circumferential profiles. Mean profiles of midventricular short-axis slices showed no significant difference between Tl-201 and FDC activity. Regional fluctuations were similar for FDG and Tl-201; the highest tracer activities were observed in the lateral wall and the lowest activities in the septum. Finally, pooled data (n=1620 segmental activities) in nine individuals showed a linear correlation (P<0.0001) between Tl-201 and FDG activity: FDG=0.76 Tl-201 + 0.23 (r=0.70). These data demonstrate the absence of major differences between regional Tl-201 and FDG activity in normal myocardium, suggesting that no separate Tl-201 and FDG SPET reference values are needed for comparison with patient studies.
引用
收藏
页码:56 / 60
页数:5
相关论文
共 12 条
[1]   FEASIBILITY OF ASSESSING REGIONAL MYOCARDIAL UPTAKE OF F-18 FLUORODEOXYGLUCOSE USING SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY [J].
BAX, JJ ;
VISSER, FC ;
VANLINGEN, A ;
HUITINK, JM ;
KAMP, O ;
VANLEEUWEN, GR ;
VISSER, GWM ;
TEULE, GJJ ;
VISSER, CA .
EUROPEAN HEART JOURNAL, 1993, 14 (12) :1675-1682
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   CIRCUMFERENTIAL WALL THICKNESS MEASUREMENTS OF THE HUMAN LEFT-VENTRICLE - REFERENCE DATA FOR TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY [J].
CLAUSEN, M ;
BICE, AN ;
CIVELEK, AC ;
HUTCHINS, GM ;
WAGNER, HN .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (09) :827-831
[4]  
DEFRONZO RA, 1979, AM J PHYSIOL, V237, pE214
[5]  
GO RT, 1985, J NUCL MED, V26, P695
[6]   QUANTITATIVE-EVALUATION OF REGIONAL SUBSTRATE METABOLISM IN THE HUMAN HEART BY POSITRON EMISSION TOMOGRAPHY [J].
HICKS, RJ ;
HERMAN, WH ;
KALFF, V ;
MOLINA, E ;
WOLFE, ER ;
HUTCHINS, G ;
SCHWAIGER, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (01) :101-111
[7]  
MELIN JA, 1986, J NUCL MED, V7, P527
[8]   CARDIAC EMISSION COMPUTED-TOMOGRAPHY - UNDERESTIMATION OF REGIONAL TRACER CONCENTRATIONS DUE TO WALL MOTION ABNORMALITIES [J].
PARODI, O ;
SCHELBERT, HR ;
SCHWAIGER, M ;
HANSEN, H ;
SELIN, C ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (06) :1083-1092
[9]  
SCHELBERT HR, 1991, CIRCULATION S1, V84, P122
[10]  
SCHWAIGER M, 1991, J NUCL MED, V32, P565