DIRECT DETERMINATION OF BENZENE IN GASOLINE BY FLOW-INJECTION FOURIER-TRANSFORM INFRARED SPECTROMETRY

被引:22
作者
GALLIGNANI, M [1 ]
GARRIGUES, S [1 ]
DELAGUARDIA, M [1 ]
机构
[1] UNIV VALENCIA,DEPT QUIM ANALIT,C-DR MOLINER 50,E-46100 BURJASSOT,SPAIN
关键词
FLOW INJECTION; INFRARED SPECTROMETRY; BENZENE; GASOLINE;
D O I
10.1016/0003-2670(93)80475-Z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Fourier transform infrared spectrometric procedure for the automated determination of benzene in gasoline was developed, based on the use of flow-injection analysis. The method permits the direct determination of benzene without any pretreatment of samples, with a limit of detection of 0.02% (v/v) and a relative standard deviation of ca. 1% [for five independent analyses of a diluted sample containing a 0.4% (v/v) of benzene]. Results found by direct analysis agreed with those obtained by off-line and on-line standard addition methods. A rapid quality control procedure was developed, based on the on-line injection of gasoline samples (diluted 1 + 9 in hexane) into a carrier stream of a 0.5% (v/v) solution of benzene in hexane; in this instance, the baseline corresponds to the upper limit tolerated by the European Economic Community's law for gasolines. Thus, the injection of diluted samples with an appropriate level of benzene must provide no peaks or negative peaks, whereas those with a benzene concentration higher than that tolerated provide positive peaks. A series of real samples were analysed by the proposed procedure and the results obtained were comparable to those given by gas chromatography.
引用
收藏
页码:267 / 274
页数:8
相关论文
共 25 条
  • [1] [Anonymous], 1987, ANN BOOK ASTM STAND, V1
  • [2] BRONDER M, 1989, LABOR PRAXIS, V13, P21
  • [3] SUPERCRITICAL FLUID CHROMATOGRAPHIC DETERMINATION OF HYDROCARBON GROUPS IN GASOLINES AND MIDDLE DISTILLATE FUELS
    CAMPBELL, RM
    DJORDJEVIC, NM
    MARKIDES, KE
    LEE, ML
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (04) : 356 - 362
  • [4] DIRECT DETERMINATION OF COPPER AND IRON IN EDIBLE OILS USING FLOW-INJECTION FLAME ATOMIC-ABSORPTION SPECTROMETRY
    CARBONELL, V
    MAURI, AR
    SALVADOR, A
    DELAGUARDIA, M
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (07) : 581 - 584
  • [5] DETERMINATION OF PHENYL ISOCYANATE IN A FLOW-INJECTION SYSTEM WITH INFRARED SPECTROMETRIC DETECTION
    CURRAN, DJ
    COLLIER, WG
    [J]. ANALYTICA CHIMICA ACTA, 1985, 177 : 259 - 262
  • [6] FLOW-INJECTION FOURIER-TRANSFORM INFRARED SPECTROMETRIC ANALYSIS
    DELAGUARDIA, M
    GARRIGUES, S
    GALLIGNANI, M
    BURGUERA, JL
    BURGUERA, M
    [J]. ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 53 - 57
  • [7] DISANZO FP, 1988, J CHROMATOGR SCI, V26, P258
  • [8] EGAZARYANTS SV, 1988, ZH ANAL KHIM, V43, P695
  • [9] GALLIGNANI M, 1991, 27 CSI BERG NORW
  • [10] GARRIIGUES S, IN PRESS TALANTA