AT-CUT QUARTZ RESONATORS FOR DETERMINATION OF VISCOELASTIC AND DIELECTRIC-PROPERTIES OF WATER GLYCEROL

被引:5
作者
SUN, HT
ZHANG, LY
YAO, X
WLODARSKI, W
机构
[1] XIAN JIAOTONG UNIV,ELECTR MAT RES LAB,XIAN 710049,PEOPLES R CHINA
[2] ROYAL MELBOURNE INST TECHNOL,DEPT COMMUN & ELECT ENGN,MELBOURNE,VIC 3001,AUSTRALIA
关键词
D O I
10.1016/0924-4247(93)00696-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electromechanical resonance phenomena of liquid-immersed quartz resonators were found to be associated with the viscoelastic and dielectric properties of glycerol and water mixtures. For AT-cut resonators immersed in the liquid, frequency dependences of impedance, phase angle, capacitance and loss tangent were carefully measured in the frequency range of oscillation. The experimental results show that the frequency spectra of capacitance and loss tangent are favorable for determining the properties of the liquid. Some preliminary relationships between the liquid properties and the resonance patterns have been made by using resonant and non-resonant data, i.e. frequency, capacitance and loss tangent.
引用
收藏
页码:208 / 212
页数:5
相关论文
共 16 条
[1]  
BOTTOM VE, 1982, INTRO QUARTZ CRYSTAL, P1
[2]  
HAUPTMANN P, 1991, SENSOR ACTUAT A-PHYS, V25, P371
[3]  
KANAZAWA KK, 1985, ANAL CHIM ACTA, V175, P99
[4]   PIEZOELECTRIC-CRYSTALS AS DETECTORS IN LIQUID-CHROMATOGRAPHY [J].
KONASH, PL ;
BASTIAANS, GJ .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1929-1931
[5]   A QUARTZ CRYSTAL BIOSENSOR FOR MEASUREMENT IN LIQUIDS [J].
KOSSLINGER, C ;
DROST, S ;
ABERL, F ;
WOLF, H ;
KOCH, S ;
WOIAS, P .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (06) :397-404
[6]   INVESTIGATION OF FILM-THICKNESS DETERMINATION BY OSCILLATING QUARTZ RESONATORS WITH LARGE MASS LOAD [J].
LU, CS ;
LEWIS, O .
JOURNAL OF APPLIED PHYSICS, 1972, 43 (11) :4385-&
[7]  
MARTIN SJ, 1991, 6TH P INT C SOLID ST, P785
[8]   SENSITIVITY ENHANCEMENT BY USE OF ACOUSTIC RESONATORS IN CW ULTRASONIC SPECTROSCOPY [J].
MILLER, JG ;
BOLEF, DI .
JOURNAL OF APPLIED PHYSICS, 1968, 39 (10) :4589-&
[9]   PIEZOELECTRIC CRYSTAL IMMUNOSENSOR FOR SENSITIVE DETECTION OF METHAMPHETAMINE (STIMULANT DRUG) IN HUMAN URINE [J].
MIURA, N ;
HIGOBASHI, H ;
SAKAI, G ;
TAKEYASU, A ;
UDA, T ;
YAMAZOE, N .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) :188-191
[10]   DETECTION OF ANTISTREPTOLYSIN O-ANTIBODY - APPLICATION OF AN INITIAL RATE METHOD OF LATEX PIEZOELECTRIC IMMUNOASSAY [J].
MURATSUGU, M ;
KUROSAWA, S ;
KAMO, N .