BALLOON DIAMETER OF THE INOUE BALLOON CATHETER DURING PERCUTANEOUS TRANSVENOUS MITRAL COMMISSUROTOMY - CLINICAL AND EXPERIMENTAL-STUDY

被引:13
作者
NAGATA, S [1 ]
ISHIKURA, F [1 ]
YAMABE, T [1 ]
AKAIKE, M [1 ]
KIMURA, K [1 ]
MIYATAKE, K [1 ]
机构
[1] NATL CARDIOVASC CTR,DEPT RADIOL,DIV CARDIOL,SUITA,OSAKA 565,JAPAN
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1991年 / 23卷 / 01期
关键词
PERCUTANEOUS MITRAL VALVULOPLASTY; INTRA-BALLOON PRESSURE; BALLOON DIAMETER;
D O I
10.1002/ccd.1810230105
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine adequate and effective balloon diameters of the Inoue balloon catheter, we reviewed clinical results and characteristics of the Inoue balloon catheter, especially the relationship between the intra-balloon pressure and the balloon diameter, experimentally and clinically, in 46 patients with mitral stenosis undergoing percutaneous transvenous mitral commissurotomy (PTMC). Mitral valve area increased from 1.1 +/- 0.3 to 2.1 +/- 0.3 cm2 in all patients after PTMC. Based on balloon diameter settings, mitral valve area increased from 1.3 +/- 0.4 to 2.3 +/- 0.5 cm2 in patients treated with a balloon setting greater than 26 mm diameter, from 1.1 +/- 0.3 to 2.0 +/- 0.5 cm2 in patients with a balloon setting at 26 mm in diameter, and from 1.1 +/- 0.4 to 1.7 +/- 0.4 cm2 in those treated with a balloon setting less than 26 mm in diameter, with an increase in mitral valve area of 1.0 +/- 0.6, 0.9 +/- 0.4, and 0.7 +/- 0.2 cm2, respectively. There was a significant difference between the increase in mitral valve area at a setting of 26 mm in diameter and that observed at a setting less than 26 mm in diameter. We next investigated differences between balloon diameter settings and actual balloon diameters measured from cineangiograms at maximum balloon inflation. The ratio of actual balloon diameter to a setting diameter of less than 26 mm was smaller than that of 26 mm. To evaluate the reason for the difference, we investigated the relationship between intra-balloon pressure and balloon diameter. In the prototype Inoue balloon catheter, intra-balloon pressure increases from 1.0 kg/cm2 at 20 mm in diameter to 2.2 kg/cm2 at 30 mm in diameter at atmospheric pressure. In conclusion, the increase in mitral valve area was inadequate when the balloon was less than 26 mm in diameter because of inadequate intra-balloon pressure. We, therefore, recommend a balloon size set above 26 mm to obtain adequate intra-balloon pressure when using the Inoue balloon catheter.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 10 条
  • [1] MITRAL REGURGITATION AFTER PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY IN ADULTS - EVALUATION BY PULSED DOPPLER ECHOCARDIOGRAPHY
    ABASCAL, VM
    WILKINS, GT
    CHOONG, CY
    BLOCK, PC
    PALACIOS, IF
    WEYMAN, AE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (02) : 257 - 263
  • [2] PERCUTANEOUS TRANS-SEPTAL BALLOON MITRAL VALVULOPLASTY - THE CHINESE EXPERIENCE IN 30 PATIENTS
    CHEN, CR
    LO, ZX
    HUANG, ZD
    INOUE, K
    CHENG, TO
    [J]. AMERICAN HEART JOURNAL, 1988, 115 (05) : 937 - 947
  • [3] GROSSMAN W, 1988, CIRCULATION S, V78, P488
  • [4] INOUE K, 1984, J THORAC CARDIOVASC, V87, P384
  • [5] RESIDUAL ATRIAL SEPTAL PERFORATION AFTER PERCUTANEOUS TRANSVENOUS MITRAL COMMISSUROTOMY WITH INOUE BALLOON CATHETER
    ISHIKURA, F
    NAGATA, S
    YASUDA, S
    YAMASHITA, N
    MIYATAKE, K
    [J]. AMERICAN HEART JOURNAL, 1990, 120 (04) : 873 - 878
  • [6] RAPID REDUCTION OF PLASMA ATRIAL NATRIURETIC PEPTIDE LEVELS DURING PERCUTANEOUS TRANSVENOUS MITRAL COMMISSUROTOMY IN PATIENTS WITH MITRAL-STENOSIS
    ISHIKURA, F
    NAGATA, S
    HIRATA, Y
    KIMURA, K
    NAKATANI, S
    TAMAI, J
    YAMAGISHI, M
    OHMORI, F
    BEPPU, S
    TAKAMIYA, M
    MIYATAKE, K
    NIMURA, Y
    [J]. CIRCULATION, 1989, 79 (01) : 47 - 50
  • [7] PERCUTANEOUS BALLOON VALVOTOMY FOR PATIENTS WITH SEVERE MITRAL-STENOSIS
    PALACIOS, I
    BLOCK, PC
    BRANDI, S
    BLANCO, P
    CASAL, H
    PULIDO, JI
    MUNOZ, S
    DEMPAIRE, G
    ORTEGA, MA
    JACOBS, M
    VLAHAKES, G
    [J]. CIRCULATION, 1987, 75 (04) : 778 - 784
  • [8] MECHANISMS OF INCREASE IN MITRAL-VALVE AREA AND INFLUENCE OF ANATOMIC FEATURES IN DOUBLE-BALLOON, CATHETER BALLOON VALVULOPLASTY IN ADULTS WITH RHEUMATIC MITRAL-STENOSIS - A DOPPLER AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC STUDY
    REID, CL
    MCKAY, CR
    CHANDRARATNA, PAN
    KAWANISHI, DT
    RAHIMTOOLA, SH
    [J]. CIRCULATION, 1987, 76 (03) : 628 - 636
  • [9] TAMAI J, 1990, KCIRCULATION, V81, P46
  • [10] WILKINS GT, 1988, BRIT HEART J, V60, P299