THE EFFECTIVE LENGTH OF A FLAT-PLATE HEAT-PIPE COVERED PARTIALLY BY A STRIP HEATER ON THE EVAPORATOR SECTION

被引:6
作者
SUN, KH [1 ]
LIU, CY [1 ]
LEONG, KC [1 ]
机构
[1] NANYANG TECHNOL UNIV,SCH MECH & PROD ENGN,SINGAPORE 2263,SINGAPORE
来源
HEAT RECOVERY SYSTEMS & CHP | 1995年 / 15卷 / 04期
关键词
D O I
10.1016/0890-4332(95)90007-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
An approximate method is presented for calculating the effective length of a flat plate heat pipe when a strip heater is partially covering the evaporator section. For a specific width of the strip heater, the optimal position to achieve a minimum effective length is found when the heater is placed symmetrically at the centre of the evaporator section. In this position, a higher value of the capillary heat transport limit can be achieved as compared to the case where the heater is placed on one side of the evaporator section.