DETERMINATION OF CORNEAL IMAGE-FORMING PROPERTIES FROM CORNEAL TOPOGRAPHY

被引:109
作者
MALONEY, RK [1 ]
BOGAN, SJ [1 ]
WARING, GO [1 ]
机构
[1] EMORY UNIV,DEPT OPHTHALMOL,ATLANTA,GA 30322
关键词
D O I
10.1016/S0002-9394(14)73521-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Keratometry provides useful information about the cornea's image-forming properties, such as corneal astigmatism, but is inaccurate on irregular corneas. Quantitative corneal topographic information is now obtainable on irregular corneas, but is difficult for the clinician to interpret. We developed a method to determine the spherical power, astigmatism, and topographic irregularity of a cornea by finding the best-fit spherocylinder that was closest to its measured topography. Keratometric measurements and two videokeratographs were gathered prospectively on 262 normal and abnormal corneas. The best-fit measurements of spherical power, astigmatism, and topographic irregularity were reproducible with one standard deviation of 0.75 diopter or better; agreement with keratometric measurements in normal eyes was good (0.60 diopter or better). Topographic irregularity averaged 0.1 diopter on precision spheres, 0.4 diopter on 146 normal eyes, 0.8 diopter on 29 eyes after radial keratotomy, 2.0 diopters on 58 eyes after penetrating keratoplasty, and 3.0 diopters on 29 eyes with advanced keratoconus. We conclude the following: basic corneal image-forming properties can be measured from videokeratographs; the properties can be determined, by our methods, on irregular corneas in which keratometry is unreliable; and topographic irregularity provides a measure of irregular astigmatism.
引用
收藏
页码:31 / 41
页数:11
相关论文
共 17 条
[1]   CLASSIFICATION OF NORMAL CORNEAL TOPOGRAPHY BASED ON COMPUTER-ASSISTED VIDEOKERATOGRAPHY [J].
BOGAN, SJ ;
WARING, GO ;
IBRAHIM, O ;
DREWS, C ;
CURTIS, L .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (07) :945-949
[2]  
BORN M, 1970, PRINCIPLES OPTICS, P211
[3]   A COMPUTER-MODEL FOR THE EVALUATION OF THE EFFECT OF CORNEAL TOPOGRAPHY ON OPTICAL-PERFORMANCE [J].
CAMP, JJ ;
MAGUIRE, LJ ;
CAMERON, BM ;
ROBB, RA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 109 (04) :379-386
[4]  
COHEN KL, 1984, INVEST OPHTH VIS SCI, V25, P323
[5]  
COURANT R, 1974, INTRO CALCULUS ANAL, V2, P122
[6]  
Dingeldein S A, 1989, Refract Corneal Surg, V5, P372
[7]   THE TOPOGRAPHY OF NORMAL CORNEAS [J].
DINGELDEIN, SA ;
KLYCE, SD .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (04) :512-518
[8]   A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS [J].
HOLLADAY, JT ;
PRAGER, TC ;
CHANDLER, TY ;
MUSGROVE, KH ;
LEWIS, JW ;
RUIZ, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :17-24
[9]  
ILSON SE, 1991, ARCH OPHTHALMOL-CHIC, V109, P349
[10]  
MACDONALD MD, 1990, ARCH OPHTHALMOL-CHIC, V108, P799