CORROSION AND PASSIVATION BEHAVIOR OF NOBLE-METAL COATED ANODES IN COPPER ELECTROWINNING APPLICATIONS

被引:3
作者
WENSLEY, D [1 ]
WARREN, IH [1 ]
机构
[1] UNIV BRITISH COLUMBIA,DEPT MET,VANCOUVER V6T 1W5,BC,CANADA
来源
METALLURGICAL TRANSACTIONS B-PROCESS METALLURGY | 1979年 / 10卷 / 04期
关键词
D O I
10.1007/BF02662550
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The performance of platinum/iridium coated titanium anodes under electrolytic conditions typical of those encountered in copper electrowinning applications has been studied. The corrosion loss of coating totalled approximately 1.5 μg/A · h during normal operation with a preferential loss of platinum from the coating. Anode potentials were observed to increase with time and the onset of complete electrode degradation was accompanied by a large increase of anode potential together with a loss of coating by spalling. The mechanism of coating loss and anode degradation is discussed. © 1979 American Society for Metals and the Metallurgical Society of AIME.