A MICROCOMPUTER-CONTROLLED SYSTEM FOR USE IN AUDITORY PHYSIOLOGY

被引:19
|
作者
FUZESSERY, ZM
GUMTOW, RG
LANE, R
机构
[1] UNIV WYOMING,DEPT PSYCHOL,LARAMIE,WY 82071
[2] DEPT ENVIRONM QUAL,DIV WATER QUAL,W CHEYENNE,WY 82002
[3] UNIV WYOMING,ART & SCI ELECTR SHOP,LARAMIE,WY 82071
基金
美国国家卫生研究院;
关键词
AUDITORY PHYSIOLOGY; ULTRASONICS; NEUROETHOLOGY; SIGNAL GENERATION; DATA ACQUISITION; MICROCOMPUTER; DIGITAL-TO-ANALOG CONVERTERS;
D O I
10.1016/0165-0270(91)90136-N
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This report describes a digitally controlled system for use in auditory physiology in which signal generation and data acquisition are under the control of a single microcomputer. The system is designed to generate the complex waveforms required in neuroethological studies, and is able to generate these signals at frequencies of up to 160 kHz with a resolution of 1 Hz. The system is built around a commercially available digital hardware system, and augmented with custom components to enhance operation speed, precision and flexibility.
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [1] A MICROCOMPUTER-CONTROLLED DIE CHANGE SYSTEM
    KUO, SG
    CHEN, CK
    COMPUTERS IN INDUSTRY, 1991, 16 (01) : 39 - 45
  • [2] Microcomputer-Controlled Positioning System.
    Sehy, Hermann H.
    Deneke, Ralf
    Reimann, Wolfgang
    Elektronik Munchen, 1987, 36 (06): : 179 - 182
  • [3] Microcomputer-controlled measurement system of exchange protect unit
    Zhao, ZB
    Zhao, J
    Zhou, QG
    ISTM/97 - 2ND INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, CONFERENCE PROCEEDINGS, 1997, : 514 - 517
  • [4] Microcomputer-controlled universal motor
    ElDin, ASZ
    ElShebiny, ME
    Khater, MM
    ISIE'96 - PROCEEDINGS OF THE IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1 AND 2, 1996, : 653 - 658
  • [5] MICROCOMPUTER-CONTROLLED TWO-PULSE GENERATOR.
    Boguslavskii, A.A.
    Shapiro, G.Ya.
    Pechenov, V.V.
    Ermilov, V.V.
    Semin, G.K.
    Instruments and experimental techniques New York, 1986, 29 (1 pt 1): : 93 - 95
  • [6] MICROCOMPUTER-CONTROLLED VISUAL STIMULATOR FOR STUDIES OF EYE-MOVEMENTS AND VISUAL EVOKED-POTENTIALS
    JANTTI, V
    AANTAA, E
    LANG, H
    LAHTI, J
    VIRTANEN, J
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (06) : 781 - 782
  • [7] How to Make an Acceleration Switch for Parabolic Flight Experiments (No. 3) A Lecture for a Beginner to Make a Microcomputer-Controlled, Electronic Device
    Natsuisaka, Makoto
    INTERNATIONAL JOURNAL OF MICROGRAVITY SCIENCE AND APPLICATION, 2013, 30 (03): : 152 - 158
  • [8] How to Make an Acceleration Switch for Parabolic Flight Experiments (No. 2) A lecture for a Beginner to Make a Microcomputer-Controlled, Electronic Device
    Natsuisaka, Makoto
    INTERNATIONAL JOURNAL OF MICROGRAVITY SCIENCE AND APPLICATION, 2013, 30 (02): : 120 - 130
  • [9] How to Make an Acceleration Switch for Parabolic Flight Experiments (No. 4) A lecture for a Beginner to Make a Microcomputer-Controlled, Electronic Device
    Natsuisaka, Makoto
    INTERNATIONAL JOURNAL OF MICROGRAVITY SCIENCE AND APPLICATION, 2013, 30 (04): : 182 - 197
  • [10] How to Make an Acceleration Switch for Parabolic Flight Experiments (No. 1) A lecture for a Beginner to Make a Microcomputer-Controlled, Electronic Device
    Natsuisaka, Makoto
    INTERNATIONAL JOURNAL OF MICROGRAVITY SCIENCE AND APPLICATION, 2013, 30 (01): : 64 - 73