CORRECTION OF PET DATA FOR PARTIAL VOLUME EFFECTS IN HUMAN CEREBRAL-CORTEX BY MR IMAGING

被引:272
作者
MELTZER, CC
LEAL, JP
MAYBERG, HS
WAGNER, HN
FROST, JJ
机构
[1] JOHNS HOPKINS MED INST, DEPT RADIOL, DIV NUCL MED, BALTIMORE, MD 21205 USA
[2] JOHNS HOPKINS MED INST, DEPT ENVIRONM HLTH SCI, BALTIMORE, MD 21205 USA
[3] JOHNS HOPKINS MED INST, DEPT NEUROSCI, BALTIMORE, MD 21205 USA
[4] JOHNS HOPKINS MED INST, DEPT NEUROL, BALTIMORE, MD 21205 USA
关键词
Alzheimer disease; Atrophy; Brain; Computed tomography; Emission; Magnetic resonance imaging;
D O I
10.1097/00004728-199007000-00011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Due to the limited spatial resolution of positron emission tomography (PET), the accuracy of quantitative measurements of regional metabolism or neuroreceptor concentration is influenced by partial volume averaging of brain with CSF, bone, and scalp. This effect is increased in the presence of cortical atrophy, as in patients with Alzheimer disease (AD). Correction for this underestimation in PET measurements is necessary for the comparison of AD patients and normal controls. We have developed a method for three-dimensional correction of human PET data using magnetic resonance (MR) imaging. A composite brain tissue image is created by summing the binary representation of nine MR images, weighted to the PET z-axis line-spread function. This composite tissue image is convolved to the resolution of the PET image. The original PET image is divided by the convolved tissue image on a pixel-by-pixel basis, resulting in an atrophy-corrected PET image in which count density represents activity per volume of brain tissue rather than spatial volume. This has been performed in [11C]carfentanil mu-opiate receptor PET studies of the temporal cortex in two AD patients and one normal volunteer. After correction, average regional increases in count density were 11% (range = 4-21%) in the normal and 46% (range = 28-99%) and 48% (range = 14-109%) in the patient studies. The accuracy of this method of partial volume correction was estimated using a spherical phantom. © 1988 Raven Press, Ltd., New York.
引用
收藏
页码:561 / 570
页数:10
相关论文
共 33 条
[21]  
KOEPPE RA, 1989, J CEREB BLOOD FLO S1, V9, pS197
[22]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .5. PHYSICAL-ANATOMICAL EFFECTS [J].
MAZZIOTTA, JC ;
PHELPS, ME ;
PLUMMER, D ;
KUHL, DE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (05) :734-743
[23]   ANATOMICAL LOCALIZATION FOR PET USING MR IMAGING [J].
MELTZER, CC ;
BRYAN, RN ;
HOLCOMB, HH ;
KIMBALL, AW ;
MAYBERG, HS ;
SADZOT, B ;
LEAL, JP ;
WAGNER, HN ;
FROST, JJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) :418-426
[24]   VARIATION WITH AGE IN THE VOLUMES OF GREY AND WHITE MATTER IN THE CEREBRAL HEMISPHERES OF MAN - MEASUREMENTS WITH AN IMAGE ANALYZER [J].
MILLER, AKH ;
ALSTON, RL ;
CORSELLIS, JAN .
NEUROPATHOLOGY AND APPLIED NEUROBIOLOGY, 1980, 6 (02) :119-132
[25]   VENTRICULAR VOLUME IN MAN COMPUTED FROM CAT SCANS [J].
PENN, RD ;
BELANGER, MG ;
YASNOFF, WA .
ANNALS OF NEUROLOGY, 1978, 3 (03) :216-223
[26]   OPIATE RECEPTOR-BINDING SITES IN HUMAN-BRAIN [J].
PFEIFFER, A ;
PASI, A ;
MEHRAEIN, P ;
HERZ, A .
BRAIN RESEARCH, 1982, 248 (01) :87-96
[27]   QUANTITATIVE NMR MEASUREMENTS OF HIPPOCAMPAL ATROPHY IN ALZHEIMER-DISEASE [J].
SEAB, JP ;
JAGUST, WJ ;
WONG, STS ;
ROOS, MS ;
REED, BR ;
BUDINGER, TF .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (02) :200-208
[28]   SOME MORPHOMETRIC ASPECTS OF THE BRAIN IN SENILE DEMENTIA OF THE ALZHEIMER TYPE [J].
TERRY, RD ;
PECK, A ;
DETERESA, R ;
SCHECHTER, R ;
HOROUPIAN, DS .
ANNALS OF NEUROLOGY, 1981, 10 (02) :184-192
[29]   REGIONAL CORRECTION OF POSITRON EMISSION TOMOGRAPHY DATA FOR THE EFFECTS OF CEREBRAL ATROPHY [J].
VIDEEN, TO ;
PERLMUTTER, JS ;
MINTUN, MA ;
RAICHLE, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (05) :662-670
[30]  
Wechsler D, 1997, WECHSLER ADULT INTEL