CORRECTION OF PET DATA FOR PARTIAL VOLUME EFFECTS IN HUMAN CEREBRAL-CORTEX BY MR IMAGING

被引:272
作者
MELTZER, CC
LEAL, JP
MAYBERG, HS
WAGNER, HN
FROST, JJ
机构
[1] JOHNS HOPKINS MED INST, DEPT RADIOL, DIV NUCL MED, BALTIMORE, MD 21205 USA
[2] JOHNS HOPKINS MED INST, DEPT ENVIRONM HLTH SCI, BALTIMORE, MD 21205 USA
[3] JOHNS HOPKINS MED INST, DEPT NEUROSCI, BALTIMORE, MD 21205 USA
[4] JOHNS HOPKINS MED INST, DEPT NEUROL, BALTIMORE, MD 21205 USA
关键词
Alzheimer disease; Atrophy; Brain; Computed tomography; Emission; Magnetic resonance imaging;
D O I
10.1097/00004728-199007000-00011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Due to the limited spatial resolution of positron emission tomography (PET), the accuracy of quantitative measurements of regional metabolism or neuroreceptor concentration is influenced by partial volume averaging of brain with CSF, bone, and scalp. This effect is increased in the presence of cortical atrophy, as in patients with Alzheimer disease (AD). Correction for this underestimation in PET measurements is necessary for the comparison of AD patients and normal controls. We have developed a method for three-dimensional correction of human PET data using magnetic resonance (MR) imaging. A composite brain tissue image is created by summing the binary representation of nine MR images, weighted to the PET z-axis line-spread function. This composite tissue image is convolved to the resolution of the PET image. The original PET image is divided by the convolved tissue image on a pixel-by-pixel basis, resulting in an atrophy-corrected PET image in which count density represents activity per volume of brain tissue rather than spatial volume. This has been performed in [11C]carfentanil mu-opiate receptor PET studies of the temporal cortex in two AD patients and one normal volunteer. After correction, average regional increases in count density were 11% (range = 4-21%) in the normal and 46% (range = 28-99%) and 48% (range = 14-109%) in the patient studies. The accuracy of this method of partial volume correction was estimated using a spherical phantom. © 1988 Raven Press, Ltd., New York.
引用
收藏
页码:561 / 570
页数:10
相关论文
共 33 条
[11]  
FROST JJ, 1985, J COMPUT ASSIST TOMO, V9, P231, DOI 10.1097/00004728-198503000-00001
[12]  
GEORGE AE, 1988, RADIOLOGY, V169, P264
[13]  
Goodman R.R., 1988, OPIATE RECEPTORS, P197
[14]  
HAXBY JV, 1985, J CEREBR BLOOD F MET, V5, P193, DOI 10.1038/jcbfm.1985.25
[15]   CORRECTION OF POSITRON EMISSION TOMOGRAPHY DATA FOR CEREBRAL ATROPHY [J].
HERSCOVITCH, P ;
AUCHUS, AP ;
GADO, M ;
CHI, D ;
RAICHLE, ME .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (01) :120-124
[16]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .6. EFFECT OF NONUNIFORM RESOLUTION [J].
HOFFMAN, EJ ;
HUANG, SC ;
PLUMMER, D ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (05) :987-999
[17]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) :299-308
[18]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .4. EFFECT OF ACCIDENTAL COINCIDENCES [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME ;
KUHL, DE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (03) :391-400
[19]  
HUANG SC, 1979, J COMPUT ASSIST TOMO, V3, P804
[20]  
KELSOE JR, 1988, ARCH GEN PSYCHIAT, V45, P533