THE PB3300 INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM

被引:13
|
作者
LUMSDEN, T
MARSHALL, WR
DIVERS, GA
RICCITELLI, SD
机构
[1] FOxS Division, Puritan-Bennett Corporation, Carlsbad, 92009, CA
来源
JOURNAL OF CLINICAL MONITORING | 1994年 / 10卷 / 01期
关键词
MONITORING; OXYGEN; CARBON DIOXIDE; ACID-BASE EQUILIBRIUM; EQUIPMENT; SENSORS;
D O I
10.1007/BF01651467
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Continuous intraarterial blood gas (IABG) monitoring is in clinical use both in the operating room and intensive care unit. This technology uses miniature, optically-based sensors that can be placed into a patient's artery. The arterial blood gas values are transduced into an optical signal that is measured by a bedside monitor on which the values are displayed. In this paper, we describe the operating principles of the PB3300 Intra-Arterial Blood Gas Monitoring System (Puritan-Bennett Corporation, FOxS Division, Carlsbad, CA). Topics include the principles of fluorescent determinations of pH, PCO2, and PO2; the optical path of the PB3300; system calibration; dye layer geometry; and clinical operation. The accuracy, precision, and drift of the system measuring tonometered aqueous standards are reported. The following values were noted for eight sensors sending data to eight monitors: system bias and precisions of 0.00 +/- 0.02 pH at a pH of 7.40, -2.5 +/- 1.5 mm Hg PCO2 at a PCO2 of 40 mm Hg, and 3.3 +/- 1.3 mm Hg PO2 at a PO2 of 80 mm Hg.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [1] MULTISITE EVALUATION OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM
    LARSON, CP
    VENDER, J
    SEIVER, A
    ANESTHESIOLOGY, 1994, 81 (03) : 543 - 552
  • [2] CLINICAL-ASSESSMENT OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM
    UCHIDA, T
    MAKITA, K
    TSUNODA, Y
    TOYOOKA, H
    AMAHA, K
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1994, 41 (01): : 64 - 70
  • [3] VALIDITY OF THE CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM DURING LIVER-TRANSPLANTATION
    NAKATSUKA, M
    POSNER, M
    FISHER, R
    RIGONI, J
    BOWEN, T
    BEESTON, J
    ANESTHESIOLOGY, 1994, 81 (3A) : A614 - A614
  • [4] CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING
    MAHUTTE, CK
    INTENSIVE CARE MEDICINE, 1994, 20 (02) : 85 - 86
  • [5] CLINICAL-ASSESSMENT OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM (VOL 41, PG 64, 1994)
    UCHIDA, T
    MAKITA, K
    TSUNODA, Y
    TOYOOKA, H
    AMAHA, K
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1994, 41 (07): : 658 - 658
  • [6] THE EVALUATION OF A NEW INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM IN THE PIG
    CLUTTONBROCK, TH
    FINK, S
    MARKLE, D
    LUTHRA, AJ
    HENDRY, SP
    JOURNAL OF CLINICAL MONITORING, 1994, 10 (06): : 387 - 391
  • [7] INTRAARTERIAL BLOOD-GAS MONITORING - COMPARISON WITH IN-VITRO BLOOD-GAS MEASUREMENTS
    PATEL, C
    ALEXANDER, L
    DOWSEY, K
    KAUFMAN, L
    BHATT, S
    ANESTHESIOLOGY, 1994, 81 (3A) : A155 - A155
  • [8] CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING - REPLY
    VENKATESH, B
    CLUTTONBROCK, TH
    HENDRY, SP
    CRITICAL CARE MEDICINE, 1995, 23 (04) : 788 - 789
  • [9] LONG-TERM EVALUATION OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM IN PATIENTS WITH SEVERE RESPIRATORY-FAILURE
    KILGER, E
    BRIEGEL, J
    SCHELLING, G
    POLASEK, J
    MANERT, W
    GROH, J
    HALLER, M
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1995, 22 (02): : 98 - 104
  • [10] OPTICAL FLUORESCENCE AND ITS APPLICATION TO AN INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM
    GEHRICH, JL
    LUBBERS, DW
    OPITZ, N
    HANSMANN, DR
    MILLER, WW
    TUSA, JK
    YAFUSO, M
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) : 117 - 132