MR CHARACTERIZATION OF BLOOD-FLOW IN NATIVE AND GRAFTED INTERNAL MAMMARY ARTERIES

被引:36
|
作者
DEBATIN, JF
STRONG, JA
SOSTMAN, HD
NEGROVILAR, R
PAINE, SS
DOUGLAS, JM
PELC, NJ
机构
[1] Department of Radiology, Stanford University Medical Center, Stanford, California, 94305, Rm HI 307
[2] Departments of Radiology, Duke University Medical Center., Durham, North Carolina
[3] Duke University Medical Center., Durham, North Carolina
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1993年 / 3卷 / 03期
关键词
ARTERIES; GRAFTS AND PROSTHESES; INTERNAL MAMMARY; CINE STUDIES; CORONARY VESSELS; STENOSIS OR OBSTRUCTION; SURGERY; FLOW QUANTIFICATION; GRAFTS; PHASE IMAGING; VASCULAR STUDIES; VELOCITY STUDIES;
D O I
10.1002/jmri.1880030303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the postoperative patient with anginal symptoms, differentiation between bypass graft compromise and nonischemic causes has until now been accomplished only by means of x-ray angiography. A noninvasive test is clearly desirable. The authors used a cine phase-contrast (PC) magnetic resonance (MR) imaging technique to characterize blood flow in native and grafted internal mammary arteries (IMAs). Ten volunteers and 15 patients who had recently undergone IMA coronary artery bypass grafting were imaged. Cine PC MR imaging was performed in the transaxial plane at the level of the pulmonary artery bifurcation. Flow in both IMAs was quantified and expressed as a percentage of cardiac output measured in the ascending aorta. In the 15 patients, flow analysis was performed in both the native and grafted IMAs. In the volunteers, IMA blood flow ranged from 2. 1 % to 4.3 % of cardiac output on the left (mean, 3.5%) and 2. 1 % to 5. 1 % (mean, 3.5%) on the right. There was considerable intersubject variability, with coefficients of variation of 10.7 % for the left and 12.3 % for the right IMA. Intrasubject variability was limited, with estimated common standard deviations of 0.45 % of cardiac output (range, 0.2%-1.1 %) for the left and 0.39% (range, 0.1%-0.6%) for the right IMA. Flow in grafted IMAs was identified in 13 of 15 patients. In one of two patients without demonstrable IMA graft flow, cardiac catheterization confirmed lack of flow. IMA graft flow varied from 28 to 164 mL/min (mean, 80.3 ml/min). This study shows the feasibility of using cine PC MR imaging as a quantitative method of evaluating blood flow in IMA coronary artery bypass grafts.
引用
收藏
页码:443 / 450
页数:8
相关论文
共 50 条
  • [1] MR CHARACTERIZATION OF BLOOD-FLOW IN NATIVE AND GRAFTED INTERNAL MAMMARY ARTERIES
    DEBATIN, JF
    STRONG, JA
    NEGROVILAR, R
    SOSTMAN, HD
    PELC, N
    HERFKENS, RJ
    RADIOLOGY, 1992, 185 : 102 - 102
  • [2] Perioperative monitoring of flow and patency in native and grafted internal mammary arteries using a combined MR protocol
    Stauder, NI
    Scheule, AM
    Hahn, U
    Fenchel, M
    Eckstein, FS
    Kramer, U
    Claussen, CD
    Miller, S
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (928): : 292 - 298
  • [3] STERNAL BLOOD-FLOW AFTER MEDIAN STERNOTOMY AND MOBILIZATION OF THE INTERNAL MAMMARY ARTERIES
    SEYFER, AE
    SHRIVER, CD
    MILLER, TR
    GRAEBER, GM
    SURGERY, 1988, 104 (05) : 899 - 904
  • [4] BLOOD-FLOW IN INTERNAL MAMMARY ARTERY
    BARNER, HB
    AMERICAN HEART JOURNAL, 1973, 86 (04) : 570 - 571
  • [5] BLOOD-FLOW VELOCITY OF INTERNAL MAMMARY ARTERY AND SAPHENOUS-VEIN GRAFTS TO THE CORONARY-ARTERIES
    BANDYK, DF
    GALBRAITH, TA
    HAASLER, GB
    ALMASSI, GH
    JOURNAL OF SURGICAL RESEARCH, 1988, 44 (04) : 342 - 351
  • [6] EFFECT OF INTERNAL MAMMARY ARTERY MOBILIZATION ON STERNAL BLOOD-FLOW
    BAHN, CH
    HOLLOWAY, GA
    CHEST, 1990, 98 (04) : 878 - 880
  • [7] STERNAL BLOOD-FLOW DURING MOBILIZATION OF THE INTERNAL THORACIC ARTERIES
    GREEN, GE
    SWISTEL, DG
    CASTRO, J
    HILLEL, Z
    THORNTON, J
    ANNALS OF THORACIC SURGERY, 1993, 55 (04): : 967 - 970
  • [8] EFFECT OF INTERNAL MAMMARY ARTERIAL MOBILIZATION ON STERNAL BLOOD-FLOW
    MELAND, NB
    CHEST, 1990, 98 (04) : 789 - 790
  • [9] Do Nuss bars compromise the blood flow of the internal mammary arteries?
    Yuksel, Mustafa
    Ozalper, Mehmet Hakan
    Bostanci, Korkut
    Ermerak, Nezih Onur
    Cimsit, Cagatay
    Tasali, Nuri
    Yildizeli, Bedrettin
    Batirel, Hasan Fevzi
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (03) : 571 - 575
  • [10] BLOOD-FLOW MEASUREMENTS IN THE AORTA AND MAJOR ARTERIES WITH MR VELOCITY MAPPING
    BOGREN, HG
    BUONOCORE, MH
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02) : 119 - 130