Modified carbon paste electrode with ionic liquid and SiO2 nanoparticles for potentiometric determination of Copper(II) ions in real samples

被引:0
作者
SoheilaSaghiri [1 ]
Ebrahimi, Mahmoud [1 ]
Beyramabadi, Safar Ali [1 ]
机构
[1] Islamic Azad Univ, Mashhad Branch, Dept Chem, Mashhad, Iran
来源
INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES | 2016年 / 5卷 / 08期
关键词
copper; Carbon paste electrode; Ionic liquid. Potentiometric; SiO2; nanopartcles;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
1,5 Diphenyl carbazone (DPC) was used as a chemical modifier for design carbon paste electrode of copper ion. A chemically modified carbon paste electrode with ionic liquid and SiO2 nanoprticles was prepared and used as a sensor for Cu2+ ion. The ionic liquid and SiO2 nanoparticles were used in the composition of the carbon paste to improve conductivity and transduction of chemical signal to electrical signal. The construction, performance, and applications of copper carbon paste electrode are described. The electrode displays a linear log [ Cu2+] versus EMF response over a wide concentration range of 1.0x10(-1)to 1.0x10(-6)M with Nernstian slope of 29.76 +/- 0.35mV/ decade with limit of detection 3.2x10- 7 over the pH range 3.8- 7.8. The electrode exhibit a Nernstian slope of 29.76 +/- 0.25mV per decade for Cu2+ ion over a wide concentration range from 1.0x10(-1)to1.0x10(- 6)M. The electrode has a fast response time (< 6 s), a satisfactory reproducibility and relatively long life time. The proposed sensor shows a good selectivity toward Cu2+ ion in comparison to other common cations and the working pH range was7.0- 11. These electrode have been successfully applied for the determination of Cu2+ ions content in various real samples.
引用
收藏
页码:326 / 331
页数:6
相关论文
共 23 条
  • [1] Novel copper(II)-selective membrane electrode based on a new synthesized Schiff base
    Akhond, Morteza
    Najafi, Mohammad Bagher
    Sharghi, Hashem
    Tashkhourian, Javad
    Naiemi, Hossein
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (02) : 331 - 337
  • [2] Buck R. P., 1994, PURE APPL CHEM, P25
  • [3] Earnshow A., 1984, HDB CHEM ELEMENTS
  • [4] Ganjali M. R., 2009, ELECTROANAL, P21
  • [5] Modified carbon paste electrodes for Cu(II) determination
    Ghaedi, Mehrorang
    Naderi, Sakineh
    Montazerozohori, Morteza
    Sahraei, Reza
    Daneshfar, Ali
    Taghavimoghadam, Narges
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (08): : 2274 - 2279
  • [6] Copper(II)-selective electrode using 2,2′-dithiodianiline as neutral carrier
    Gholivand, MB
    Nozari, N
    [J]. TALANTA, 2001, 54 (04) : 597 - 602
  • [7] POLYMER FILM CHEMICALLY MODIFIED ELECTRODE AS A POTENTIOMETRIC SENSOR
    HEINEMAN, WR
    WIECK, HJ
    YACYNYCH, AM
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (02) : 345 - 346
  • [8] Carbon paste electrode modified with silver thimerosal for the potentiometric flow injection analysis of silver(I)
    Ibrahim, H
    [J]. ANALYTICA CHIMICA ACTA, 2005, 545 (02) : 158 - 165
  • [9] Laithinen H. A., 1979, ANAL CHEM, P15
  • [10] Marston H. R., 1952, PHYSIOL REV, P56