APPLICATION OF PHOTOACOUSTIC SPECTROMETRY TO FLOW-INJECTION ANALYSIS

被引:11
|
作者
CARRER, I
CUSMAI, P
ZANZOTTERA, E
MARTINOTTI, W
REALINI, F
机构
[1] ENEL SPA,CTR RIC AMBIENTE & MAT,I-20134 MILAN,ITALY
[2] CISE SPA,I-20134 MILAN,ITALY
[3] ASTA SRL,I-20133 MILAN,ITALY
关键词
PHOTOACOUSTIC SPECTROMETRY; PULSED LASER; FLOW INJECTION; NUTRIENTS; IRON; FRESH WATER;
D O I
10.1016/0003-2670(94)00399-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Photoacoustic spectrometry (PAS) based on pulsed laser excitation has been coupled to flow-injection analysis (FIA) to detect nitrite, nitrate, iron, ammonia, and phosphate ions in water with the aim to verify its potentiality with respect to conventional FIA systems. Excitation has been performed by means of a Nd:YAG laser with a 2nd harmonic generation and a dye laser; a conventional now-injection cell has been used as photoacoustic cell. Standard solutions and real samples such as ground water, river water, fog and waste water have been analyzed. A good agreement has been obtained between the results of the proposed technique and those of traditional laboratory techniques. The best analytical configuration, in terms of loop length and integration time, has been also defined. The performance as limit of detection (LOD) was comparable for both techniques. The main points to be developed in order to improve the analytical response of PAS-FIA are reported.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 50 条
  • [1] SORBENT EXTRACTION IN FLOW-INJECTION ANALYSIS AND ITS APPLICATION TO ENHANCEMENT OF ATOMIC SPECTROMETRY
    RUZICKA, J
    ARNDAL, A
    ANALYTICA CHIMICA ACTA, 1989, 216 (1-2) : 243 - 255
  • [2] NEW INJECTION VALVES AND THEIR APPLICATION IN FLOW-INJECTION ANALYSIS
    MOLLER, J
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 329 (06): : 685 - 687
  • [3] FLOW-INJECTION ATOMIC SPECTROMETRY
    TYSON, JF
    SPECTROCHIMICA ACTA REVIEWS, 1991, 14 (03): : 169 - 233
  • [5] Flow-injection analysis in atomic absorption spectrometry (review)
    Begak, OY
    Borodin, AV
    INDUSTRIAL LABORATORY, 1998, 64 (06): : 371 - 381
  • [6] APPLICATION OF A FLOW-INJECTION SYSTEM IN WINE ANALYSIS
    KOTORMAN, M
    SIMON, ML
    SZAJANI, B
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1991, 39 (05) : 909 - 910
  • [7] SOME APPLICATION ASPECTS OF FLOW-INJECTION ANALYSIS
    VANSTADEN, JF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 182 (AUG): : 23 - ANYL
  • [8] APPLICATION OF FLOW-INJECTION ANALYSIS TO THE DETERMINATION OF GERMANIUM
    SHIMADA, K
    NAKAJIMA, M
    WAKABAYASHI, H
    YAMATO, S
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1989, 37 (04) : 1095 - 1096
  • [9] Application of porphyrins in flow-injection analysis: A review
    van Staden, Jacobus F.
    Stefan-van Staden, Raluca I.
    TALANTA, 2010, 80 (05) : 1598 - 1605
  • [10] RADIOMETRIC DETECTION IN FLOW-INJECTION ANALYSIS (RADIOMETRIC FLOW-INJECTION ANALYSIS)
    MYINT, U
    BA, H
    MYOE, KM
    KYWE, A
    THIDA
    TOLGYESSY, J
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1994, 187 (02): : 117 - 122