SENSITIVE FLOW-INJECTION SPECTROFLUOROMETRIC METHOD TO DETERMINE ALUMINUM(III) IN WATER

被引:16
作者
CARRILLO, F [1 ]
PEREZ, C [1 ]
CAMARA, C [1 ]
机构
[1] UNIV COMPLUTENSE,FAC QUIM,DEPT QUIM ANALIT,E-28040 MADRID,SPAIN
关键词
FLUOROMETRY; FLOW SYSTEM; ALUMINUM; WATERS;
D O I
10.1016/0003-2670(92)80012-V
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A room-temperature flow injection-spectrofluorimetric method is presented for the determination of Al(III), based on the use of Eriochrome Red B in the presence of H2MTA+-HMTA (HMTA = hexamethylenetetramine) or HOAc-OAc- buffer. Various chemical and physical variables affecting the reaction in the flow system were evaluated. The proposed method is very sensitive. with a detection limit of 0.3 ng ml-1 and a precision at the 20 ng ml-1 level of 2.5%. The calibration range is linear up to 1-mu-g ml-1. The method has been successfully applied to the determination of Al(III) in tap and mineral waters.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 8 条
[1]   FLOW-INJECTION AND LIQUID-CHROMATOGRAPHIC DETERMINATION OF ALUMINUM BASED ON ITS FLUORIMETRIC REACTION WITH 8-HYDROXYQUINOLINE-5-SULFONIC ACID IN A MICELLAR MEDIUM [J].
ALONSO, JIG ;
GARCIA, AL ;
SANZMEDEL, A ;
GONZALEZ, EB ;
EBDON, L ;
JONES, P .
ANALYTICA CHIMICA ACTA, 1989, 225 (02) :339-350
[2]   CHEMILUMINESCENCE DETERMINATION OF VITAMIN-B12 BY A FLOW-INJECTION METHOD [J].
ZHOU, YK ;
LI, H ;
LIU, Y ;
LIANG, GY .
ANALYTICA CHIMICA ACTA, 1991, 243 (01) :127-130
[3]   ONLINE ALUMINUM PRECONCENTRATION ON CHELATING RESIN AND ITS FIA SPECTROFLUOROMETRIC DETERMINATION IN FOODS AND DIALYSIS CONCENTRATES [J].
FERNANDEZ, P ;
CONDE, CP ;
GUTIERREZ, A ;
CAMARA, C .
TALANTA, 1991, 38 (12) :1387-1392
[4]   FLUORIMETRIC DETERMINATION OF ALUMINUM WITH MORIN AFTER EXTRACTION WITH ISOBUTYL METHYL KETONE .1. FLUORESCENCE OF THE ALUMINUM - MORIN COMPLEX IN AN ISOBUTYL METHYL KETONE - ETHANOL - WATER-SYSTEM [J].
HERNANDEZ, FH ;
ESCRICHE, JM .
ANALYST, 1984, 109 (12) :1585-1588
[5]   FLOW-INJECTION ION-EXCHANGE PRECONCENTRATION FOR THE DETERMINATION OF ALUMINUM BY ATOMIC-ABSORPTION SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
GARCIA, MRP ;
GARCIA, MED ;
MEDEL, AS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (07) :699-703
[6]   METAL CHELATE FLUORESCENCE ENHANCEMENT IN MICELLAR MEDIA - MECHANISMS OF SURFACTANT ACTION [J].
SANZMEDEL, A ;
DELACAMPA, RF ;
ALONSO, JIG .
ANALYST, 1987, 112 (04) :493-497
[7]   COMPARISON OF ANION-EXCHANGE METHODS FOR PRECONCENTRATION OF TRACE ALUMINUM [J].
SARZANINI, C ;
MENTASTI, E ;
PORTA, V ;
GENNARO, MC .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :484-486
[8]   MATRIX EFFECTS IN THE DETERMINATION OF ALUMINUM IN DIALYSIS FLUIDS BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
WOOLFSON, AD ;
GRACEY, GM .
ANALYST, 1987, 112 (10) :1387-1389