MOLTENO IMPLANT-SURGERY FOR ADVANCED GLAUCOMA

被引:21
|
作者
THOMAS, R
GIESER, SC
BILLSON, F
机构
[1] JOHNS HOPKINS UNIV HOSP,DANA CTR PREVENT BUNDNESS,BALTIMORE,MD 21205
[2] CHRISTIAN MED COLL & HOSP,DEPT OPHTHALMOL,VELLORE,TAMIL NADU,INDIA
[3] UNIV SYDNEY,INST SAVE SIGHT & EYE HLTH,DARLINGHURST,NSW 2010,AUSTRALIA
关键词
ADVANCED GLAUCOMA; MOLTENO IMPLANT;
D O I
10.1111/j.1442-9071.1995.tb01639.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The use of adjunctive antimitotics with conventional filtering surgery appears to have decreased the need for Molteno implants in glaucomas with a poor prognosis. We review the current status, results and complications of Molteno implants. Methods: Review of the literature and practical experience from two university departments of ophthalmology. Results: Improvements in the design and surgical techniques for Molteno implants have decreased the incidence of over filtration, but this and other complications continue to pose problems. Increased success rates may be possible if antimitotics are used with Molteno implants. Conclusion: Molteno implants continue to be an option when conventional filtration with or without antimitotics has failed; they continue to be regarded as a last resort for filtration. The use of antimitotics to increase the success rate of Molteno implants is not proven, but merits further investigation.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 50 条
  • [31] EFFICACY AND SAFETY OF HYPROMELLOSE IN OCULAR IMPLANT-SURGERY
    ROSEN, PA
    BROOKS, AMV
    RAMSAY, RJ
    GULLIFER, KP
    WOLFE, RJB
    GILLIES, WE
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1987, 15 (03): : 193 - 199
  • [32] REPAIR OF MOLTENO IMPLANT DURING SURGERY
    KOONER, KS
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 117 (05) : 673 - 673
  • [33] FATAL SEQUEL TO DENTAL IMPLANT-SURGERY
    GIRDLER, NM
    JOURNAL OF ORAL REHABILITATION, 1994, 21 (06) : 721 - 722
  • [34] HISTOPATHOLOGIC STUDY OF THE MOLTENO GLAUCOMA IMPLANT IN 3 PATIENTS
    RUBIN, B
    CHAN, CC
    BURNIER, M
    MUNION, L
    FREEDMAN, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 110 (04) : 371 - 379
  • [35] Surgical Management of Glaucoma With Molteno3 Implant
    Valimaki, Juha
    JOURNAL OF GLAUCOMA, 2012, 21 (01) : 7 - 11
  • [36] CURRENT TRENDS IN JOINT IMPLANT-SURGERY
    LONGTON, EB
    PRACTITIONER, 1982, 226 (1372) : 1676 - &
  • [37] PROBLEMS AND COMPLICATIONS OF COCHLEAR IMPLANT-SURGERY
    COHEN, NL
    ROSENBERG, R
    GOLDSTEIN, S
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1987, 96 (01): : 14 - 15
  • [38] LENS IMPLANT-SURGERY IN PARS PLANITIS
    MICHELSON, JB
    FRIEDLAENDER, MH
    NOZIK, RA
    OPHTHALMOLOGY, 1990, 97 (08) : 1023 - 1026
  • [39] ANTERIOR SEGMENT COMPLICATIONS OF IMPLANT-SURGERY
    BYRON, HM
    OPHTHALMOLOGY, 1979, 86 (04) : 621 - 624
  • [40] COMPARISON OF THE BAERVELDT GLAUCOMA IMPLANT WITH THE DOUBLE-PLATE MOLTENO DRAINAGE IMPLANT
    SMITH, MF
    DOYLE, JW
    SHERWOOD, MB
    ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (04) : 444 - 447