A PRACTICAL APPROACH TO MEASURING AN INTRAVASCULAR ULTRASONOGRAPHIC IMAGING-SYSTEM BEAM PATTERN

被引:0
作者
BERNIER, CA [1 ]
HUNTSMAN, L [1 ]
MARTIN, R [1 ]
机构
[1] UNIV WASHINGTON,CTR BIOENGN WD12,SEATTLE,WA
关键词
INTRAVASCULAR ULTRASONOGRAPHY; BEAM PATTERN; POINT SPREAD FUNCTION; TRANSDUCER; CHARACTERIZATION; RESOLUTION;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Characterizing beam patterns of miniature (1 to 3 mm diameter) catheter sonographic systems operating at 15 to 50 MHz is difficult and such information is often not provided by manufacturers. For investigators in the field, quantitative information describing catheters and their systems is important to properly understand measurements and images. A practical means of characterizing the system is described that can be assembled in most laboratories and used with existing catheter systems. The ultrasonic beam pattern from an intravascular sonographic transducer is characterized in three dimensions using images generated from a 150 mu m diameter spherical target. Experiments are described in which the point spread function or beam pattern is mapped throughout the imaging system field-of-view. Using this approach, the beam pattern and resolutions for a commercial 1.18 mm diameter, 20 MHz intravascular catheter were measured.
引用
收藏
页码:367 / 373
页数:7
相关论文
共 13 条
[1]  
BARRETTHH, 1981, RADIOLOGICAL IMAGING
[2]   QUANTITATIVE CONTRAST MEASUREMENTS IN B-MODE IMAGES COMPARISON BETWEEN EXPERIMENT AND THEORY [J].
BLY, SHP ;
LEECHAHAL, D ;
FOSTER, DR ;
PATTERSON, MS ;
FOSTER, FS ;
HUNT, JW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (03) :197-208
[3]  
Bom N, 1989, Int J Card Imaging, V4, P79, DOI 10.1007/BF01745137
[4]  
CAVAYE DM, 1992, SURG CLIN N AM, V72, P823
[5]   A DIGITAL ANNULAR ARRAY PROTOTYPE SCANNER FOR REALTIME ULTRASOUND IMAGING [J].
FOSTER, FS ;
LARSON, JD ;
PITTARO, RJ ;
CORL, PD ;
GREENSTEIN, AP ;
LUM, PK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (07) :661-672
[6]   TRANSDUCER BEAM PATTERN TEST OBJECT [J].
HEFNER, LV ;
PARKS, JA ;
GOLDSTEIN, A .
JOURNAL OF CLINICAL ULTRASOUND, 1980, 8 (01) :5-10
[7]  
Hodgson J M, 1989, Int J Card Imaging, V4, P187, DOI 10.1007/BF01745149
[8]   APPLICATION OF A NEW PHASED-ARRAY ULTRASOUND IMAGING CATHETER IN THE ASSESSMENT OF VASCULAR DIMENSIONS - INVIVO COMPARISON TO CINEANGIOGRAPHY [J].
NISSEN, SE ;
GRINES, CL ;
GURLEY, JC ;
SUBLETT, K ;
HAYNIE, D ;
DIAZ, C ;
BOOTH, DC ;
DEMARIA, AN .
CIRCULATION, 1990, 81 (02) :660-666
[9]   THE IMPROVEMENT AND QUANTITATIVE ASSESSMENT OF B-MODE IMAGES PRODUCED BY AN ANNULAR ARRAY CONE HYBRID [J].
PATTERSON, MS ;
FOSTER, FS .
ULTRASONIC IMAGING, 1983, 5 (03) :195-213
[10]  
THIJSSEN JM, 1990, J ULTRAS MED, V9, P215