NOVEL FORCE TRANSDUCER FOR THE MEASUREMENT OF TENDON FORCE IN-VIVO

被引:25
|
作者
PLATT, D
WILSON, AM
TIMBS, A
WRIGHT, IM
GOODSHIP, AE
机构
[1] UNIV CAMBRIDGE,DEPT ENGN,CAMBRIDGE CB2 1PZ,ENGLAND
[2] DEPT ANAT,COMPARAT ORTHOPAED RES UNIT,BRISTOL,AVON,ENGLAND
关键词
Buckle transducers - Tendon force - Tendon strain;
D O I
10.1016/0021-9290(94)90198-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
[No abstract available]
引用
收藏
页码:1489 / 1493
页数:5
相关论文
共 50 条
  • [31] THEORETICAL-ANALYSIS OF AN IMPLANTABLE FORCE TRANSDUCER FOR TENDON AND LIGAMENT STRUCTURES
    XU, WS
    BUTLER, DL
    STOUFFER, DC
    GROOD, ES
    GLOS, DL
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (02): : 170 - 177
  • [32] The use of an implantable force transducer to measure patellar tendon forces in goats
    Korvick, DL
    Cummings, JF
    Grood, ES
    Holden, JP
    Feder, SM
    Butler, DL
    JOURNAL OF BIOMECHANICS, 1996, 29 (04) : 557 - 561
  • [33] Development and metrological characterization of a precision force transducer for static force measurement related applications
    Kumar, Harish
    Sharma, Chitra
    Arora, P. K.
    Moona, Girija
    Kumar, Anil
    MEASUREMENT, 2016, 88 : 77 - 86
  • [34] Individual muscle contributions to the in vivo Achilles tendon force
    Arndt, AN
    Komi, PV
    Brüggemann, GP
    Lukkariniemi, J
    CLINICAL BIOMECHANICS, 1998, 13 (07) : 532 - 541
  • [35] CAPACITIVE TRANSDUCER FOR CONTINUOUS MEASUREMENT OF VERTICAL FOOT FORCE
    MIYAZAKI, S
    ISHIDA, A
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (04) : 309 - 316
  • [36] Capacitive transducer for continuous measurement of vertical foot force
    Miyazaki, S.
    Ishida, A.
    Medical and Biological Engineering and Computing, 1984, 22 (04): : 309 - 316
  • [37] Measurement of trocar insertion force using a piezoelectric transducer
    Ng, PS
    Sahota, DS
    Yuen, PM
    JOURNAL OF THE AMERICAN ASSOCIATION OF GYNECOLOGIC LAPAROSCOPISTS, 2003, 10 (04): : 534 - 538
  • [38] Measurement of in-vivo force response of intra-abdominal soft tissues for surgical simulation
    Tay, BK
    Stylopoulos, N
    De, S
    Rattner, DW
    Srinivasan, MA
    MEDICINE MEETS VIRTUAL REALITY 02/10: DIGITAL UPGRADES: APPLYING MOORES LAW TO HEALTH, 2002, 85 : 514 - 519
  • [39] IN-VIVO TENDON TENSION AND BONE STRAIN MEASUREMENT AND CORRELATION
    BARNES, GRG
    PINDER, DN
    JOURNAL OF BIOMECHANICS, 1974, 7 (01) : 35 - 42
  • [40] Calibration and application of an intra-articular force transducer for the measurement of patellar tendon graft forces:: an in situ evaluation
    Fleming, BC
    Good, L
    Peura, GD
    Beynnon, BD
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (04): : 393 - 398