GLUTAMATE BIOSENSORS BASED ON ELECTRICAL COMMUNICATION BETWEEN L-GLUTAMATE OXIDASE AND A FLEXIBLE REDOX POLYMER

被引:25
作者
HALE, PD
LEE, HS
OKAMOTO, Y
SKOTHEIM, TA
机构
[1] POLYTECH INST NEW YORK,DEPT CHEM,BROOKLYN,NY 11201
[2] BROOKHAVEN NATL LAB,DEPT CHEM,UPTON,NY 11973
关键词
BIOSENSOR; GLUTAMATE; OXIDASE; REDOX POLYMER; ELECTRON TRANSFER RELAYS;
D O I
10.1080/00032719108052911
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrical communication between the flavin adenine dinucleotide redox centers of L-glutamate oxidase and a conventional carbon electrode has been achieved using a new electron transfer relay system based on a ferrocene-modified siloxane-ethylene oxide branch copolymer. Using cyclic voltammetry and stationary potential experiments, it was shown that spectrographic graphite electrodes modified with this redox polymer and L-glutamate oxidase respond rapidly to addition of glutamate, with steady-state current responses achieved in less than 1 min. At an applied potential of +400 mV (vs. Ag/AgCl), a lower detection limit of approximately 0.01 mM and an apparent Michaelis-Menten constant, K(M)app, of 0.20 mM were determined.
引用
收藏
页码:345 / 356
页数:12
相关论文
共 17 条
[1]   ENZYME ELECTRODE FOR DETERMINATION OF L-GLUTAMIC ACID [J].
AHN, BK ;
WOLFSON, SK ;
YAO, SJ .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1975, 2 (02) :142-153
[2]   A NOVEL L-GLUTAMATE OXIDASE FROM STREPTOMYCES-ENDUS - PURIFICATION AND PROPERTIES [J].
BOHMER, A ;
MULLER, A ;
PASSARGE, M ;
LIEBS, P ;
HONECK, H ;
MULLER, HG .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1989, 182 (02) :327-332
[3]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[4]  
COOPER JR, 1986, BIOCH BASIS NEUROPHA, P161
[5]   APPLICATION OF IMMOBILIZED NAD+ IN AN ENZYME ELECTRODE AND IN MODEL ENZYME REACTORS [J].
DAVIES, P ;
MOSBACH, K .
BIOCHIMICA ET BIOPHYSICA ACTA, 1974, 370 (02) :329-338
[6]   A GLUCOSE ELECTRODE BASED ON CARBON PASTE CHEMICALLY MODIFIED WITH A FERROCENE-CONTAINING SILOXANE POLYMER AND GLUCOSE-OXIDASE, COATED WITH A POLY(ESTER-SULFONIC ACID) CATION-EXCHANGER [J].
GORTON, L ;
KARAN, HI ;
HALE, PD ;
INAGAKI, T ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1990, 228 (01) :23-30
[7]   ELECTRODE FOR DETERMINATION OF GLUTAMINE [J].
GUILBAULT, GG ;
SHU, FR .
ANALYTICA CHIMICA ACTA, 1971, 56 (03) :333-+
[8]   A NEW CLASS OF AMPEROMETRIC BIOSENSOR INCORPORATING A POLYMERIC ELECTRON-TRANSFER MEDIATOR [J].
HALE, PD ;
INAGAKI, T ;
KARAN, HI ;
OKAMOTO, Y ;
SKOTHEIM, TA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (09) :3482-3484
[9]   FERROCENE-MODIFIED SILOXANE POLYMERS AS ELECTRON RELAY SYSTEMS IN AMPEROMETRIC GLUCOSE SENSORS [J].
HALE, PD ;
BOGUSLAVSKY, LI ;
INAGAKI, T ;
LEE, HS ;
SKOTHEIM, TA ;
KARAN, HI ;
OKAMOTO, Y .
MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1990, 190 :251-258
[10]   AMPEROMETRIC GLYCOLATE SENSORS BASED ON GLYCOLATE OXIDASE AND POLYMERIC ELECTRON-TRANSFER MEDIATORS [J].
HALE, PD ;
INAGAKI, T ;
LEE, HS ;
KARAN, HI ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1990, 228 (01) :31-37