GLUTAMATE BIOSENSORS BASED ON ELECTRICAL COMMUNICATION BETWEEN L-GLUTAMATE OXIDASE AND A FLEXIBLE REDOX POLYMER

被引:25
作者
HALE, PD
LEE, HS
OKAMOTO, Y
SKOTHEIM, TA
机构
[1] POLYTECH INST NEW YORK,DEPT CHEM,BROOKLYN,NY 11201
[2] BROOKHAVEN NATL LAB,DEPT CHEM,UPTON,NY 11973
关键词
BIOSENSOR; GLUTAMATE; OXIDASE; REDOX POLYMER; ELECTRON TRANSFER RELAYS;
D O I
10.1080/00032719108052911
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrical communication between the flavin adenine dinucleotide redox centers of L-glutamate oxidase and a conventional carbon electrode has been achieved using a new electron transfer relay system based on a ferrocene-modified siloxane-ethylene oxide branch copolymer. Using cyclic voltammetry and stationary potential experiments, it was shown that spectrographic graphite electrodes modified with this redox polymer and L-glutamate oxidase respond rapidly to addition of glutamate, with steady-state current responses achieved in less than 1 min. At an applied potential of +400 mV (vs. Ag/AgCl), a lower detection limit of approximately 0.01 mM and an apparent Michaelis-Menten constant, K(M)app, of 0.20 mM were determined.
引用
收藏
页码:345 / 356
页数:12
相关论文
共 17 条
  • [1] ENZYME ELECTRODE FOR DETERMINATION OF L-GLUTAMIC ACID
    AHN, BK
    WOLFSON, SK
    YAO, SJ
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1975, 2 (02): : 142 - 153
  • [2] A NOVEL L-GLUTAMATE OXIDASE FROM STREPTOMYCES-ENDUS - PURIFICATION AND PROPERTIES
    BOHMER, A
    MULLER, A
    PASSARGE, M
    LIEBS, P
    HONECK, H
    MULLER, HG
    [J]. EUROPEAN JOURNAL OF BIOCHEMISTRY, 1989, 182 (02): : 327 - 332
  • [3] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [4] COOPER JR, 1986, BIOCH BASIS NEUROPHA, P161
  • [5] APPLICATION OF IMMOBILIZED NAD+ IN AN ENZYME ELECTRODE AND IN MODEL ENZYME REACTORS
    DAVIES, P
    MOSBACH, K
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1974, 370 (02) : 329 - 338
  • [6] A GLUCOSE ELECTRODE BASED ON CARBON PASTE CHEMICALLY MODIFIED WITH A FERROCENE-CONTAINING SILOXANE POLYMER AND GLUCOSE-OXIDASE, COATED WITH A POLY(ESTER-SULFONIC ACID) CATION-EXCHANGER
    GORTON, L
    KARAN, HI
    HALE, PD
    INAGAKI, T
    OKAMOTO, Y
    SKOTHEIM, TA
    [J]. ANALYTICA CHIMICA ACTA, 1990, 228 (01) : 23 - 30
  • [7] ELECTRODE FOR DETERMINATION OF GLUTAMINE
    GUILBAULT, GG
    SHU, FR
    [J]. ANALYTICA CHIMICA ACTA, 1971, 56 (03) : 333 - +
  • [8] A NEW CLASS OF AMPEROMETRIC BIOSENSOR INCORPORATING A POLYMERIC ELECTRON-TRANSFER MEDIATOR
    HALE, PD
    INAGAKI, T
    KARAN, HI
    OKAMOTO, Y
    SKOTHEIM, TA
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (09) : 3482 - 3484
  • [9] FERROCENE-MODIFIED SILOXANE POLYMERS AS ELECTRON RELAY SYSTEMS IN AMPEROMETRIC GLUCOSE SENSORS
    HALE, PD
    BOGUSLAVSKY, LI
    INAGAKI, T
    LEE, HS
    SKOTHEIM, TA
    KARAN, HI
    OKAMOTO, Y
    [J]. MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1990, 190 : 251 - 258
  • [10] AMPEROMETRIC GLYCOLATE SENSORS BASED ON GLYCOLATE OXIDASE AND POLYMERIC ELECTRON-TRANSFER MEDIATORS
    HALE, PD
    INAGAKI, T
    LEE, HS
    KARAN, HI
    OKAMOTO, Y
    SKOTHEIM, TA
    [J]. ANALYTICA CHIMICA ACTA, 1990, 228 (01) : 31 - 37