LUMPED-PARAMETER MODEL FOR MODEL-IV FLUID CATALYTIC CRACKING UNITS

被引:1
|
作者
TATRAI, FZ
LANT, PA
LEE, PL
CAMERON, IT
NEWELL, RB
机构
[1] University of Queensland, Department of Chemical Engineering, Queensland
关键词
DYNAMIC MODELING; MODEL REDUCTION; FLUID CATALITIC CRACKING; PROCESS CONTROL;
D O I
10.1016/0098-1354(94)80030-8
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The state-of-die-art in structure preserving model reduction techniques is restricted to employing linear process descriptions, thereby requiring the linearisation of the original (nonlinear) 'reference' model. If a particular model consists of an explicitly time dependent set of ODEs and of position dependent ODE's (which are only implicit functions of time), the linearisation must be preceded by a transformation of the position dependent ODE-s to make their time dependency explicit. The technique presented in this paper is based on the application of the continuity equation to the integral average properties for which tale gradient is given in form of position dependent ODEs. This method overcomes the problem of the dramatic increase in the number of states (characteristic of the conventional techniques based on the discretisation of the spatial coordinates), but still retains model accuracy. The use of the technique is demonstrated on the rigorous physico-chemical model of the reactor/regenerator section of a Model IV Fluid Catalytic Cracking Unit (FCCU) developed by McFarlane ef al (1990). Open loop and closed loop responses of the original 'reference' and 'lumped' models are compared. The adequacy of the lumping is demonstrated.
引用
收藏
页码:S177 / S181
页数:5
相关论文
共 50 条
  • [1] MODIFICATIONS TO MODEL-IV FLUID CATALYTIC CRACKING UNITS TO IMPROVE DYNAMIC PERFORMANCE
    HUQ, I
    MORARI, M
    SORENSEN, RC
    AICHE JOURNAL, 1995, 41 (06) : 1481 - 1499
  • [2] DYNAMIC SIMULATOR FOR A MODEL-IV FLUID CATALYTIC CRACKING UNIT
    MCFARLANE, RC
    REINEMAN, RC
    BARTEE, JF
    GEORGAKIS, C
    COMPUTERS & CHEMICAL ENGINEERING, 1993, 17 (03) : 275 - 300
  • [3] A LUMPED-PARAMETER MODEL FOR INFILTRATION
    PINGOUD, K
    JOURNAL OF HYDROLOGY, 1982, 57 (1-2) : 175 - 185
  • [4] TRANS-CAPILLARY FLUID EXCHANGE - LUMPED-PARAMETER MODEL
    MOISEEVA, IN
    BIOFIZIKA, 1984, 29 (01): : 126 - 129
  • [5] SENSITIVITY ANALYSIS OF A LUMPED-PARAMETER MODEL FOR INFILTRATION
    PINGOUD, K
    JOURNAL OF HYDROLOGY, 1984, 67 (1-4) : 97 - 113
  • [6] LUMPED-PARAMETER MODEL FOR INVIVO COCHLEAR STIMULATION
    SUESSERMAN, MF
    SPELMAN, FA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (03) : 237 - 245
  • [7] Lumped-parameter thermal model for induction machines
    Durán, MJ
    Fernández, J
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (04) : 791 - 792
  • [8] Lumped-parameter inertia model for flexure hinges
    Lobontiu, N
    Garcia, E
    MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2004, 32 (01) : 73 - 99
  • [9] Establishment of lumped model for hydrotreated residual fluid catalytic cracking
    Wang, Jian-Ping
    Xu, Xian-Kun
    Weng, Hui-Xin
    Fang, Xiang-Chen
    Hu, Chang-Lu
    Shiyou Xuebao, Shiyou Jiagong/Acta Petrolei Sinica (Petroleum Processing Section), 2006, 22 (04): : 44 - 48
  • [10] PARAMETER SENSITIVITY ANALYSIS OF A LUMPED-PARAMETER MODEL OF LYMPHANGIONS IN SERIES
    Jamalian, Samira
    Moore, James E., Jr.
    Bertram, Christopher D.
    Richardson, Will
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 345 - 346