End-tidal concentration of sevoflurane for preventing rocuronium-induced withdrawal of the arm in pediatric patients

被引:2
作者
Yeom, Jong Hoon [1 ]
Kim, Yong Oh [1 ]
Lee, Jae Min [1 ]
Jeon, Woo Jae [1 ]
机构
[1] Hanyang Univ, Guri Hosp, Dept Anesthesiol & Pain Med, 249-1 Kyomun Dong, Guri 471701, South Korea
关键词
Pain; Rocuronium; Sevoflurane; Withdrawal;
D O I
10.4097/kjae.2014.66.4.274
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: During induction of general anesthesia, the intravenous injection of rocuronium is often associated with withdrawal movement of the arm due to pain, and this abrupt withdrawal may result in dislodgement of the venous catheter, injury, or inadequate injection of rocuronium. We performed this study to evaluate the 50 and 95% effective endtidal concentrations of sevoflurane (ETsev) for preventing rocuronium-induced withdrawal of the arm. Methods: We conducted a prospective double-blind study in 31 pediatric patients. After free flow of lactated Ringer's IV fluid was confirmed, anesthesia was induced in the patients by using 2.5% thiopental sodium (4 mg/kg) and sevoflurane (4 vol%) with 6 L/min of oxygen. When the target ETsev was reached, preservative-free 1% lidocaine (1.5 mg/kg) was intravenously injected during manual venous occlusion and rocuronium (0.6 mg/kg) was injected after lidocaine injection under free-flow intravenous fluid. A nurse who was an investigator and was blinded to the ETsev injected the rocuronium. The nurse evaluated the response. Results: Non-withdrawal movement was observed in 5 out of 11 patients with ETsev 3.0 vol% and in 5 out of 6 patients with ETsev 3.5 vol%. By Dixon's up-and-down method, the 50% effective concentration (EC50) of sevoflurane for non-withdrawal movement at rocuronium injection was 3.1 +/- 0.4 vol%. A logistic regression curve of the probability of non-withdrawal movements showed that the 50% effective ETsev for abolishing withdrawal movement at rocuronium injection was 2.9 vol% (95% confidence interval [CI] 2.4-3.8 vol%) and the 95% effective ETsev was 4.3 vol% (95% CI 3.6-9.8 vol%). Conclusions: This study showed that the 50 and 95% effective ETsev that prevent withdrawal movement at rocuronium injection are 2.9 and 4.3 vol%, respectively.
引用
收藏
页码:274 / 277
页数:4
相关论文
共 26 条
  • [21] Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired-end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
    Dias, Raylene
    Dave, Nandini
    Agrawal, Barkha
    Baghele, Aarti
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (04) : 277 - 283
  • [22] Efficacy and Safety of Sugammadex for the Reversal of Rocuronium-Induced Neuromuscular Blockade in Patients with End-Stage Renal Disease: A Systematic Review and Meta-Analysis
    Kim, Young-Sung
    Lim, Byung-Gun
    Won, Young-Ju
    Oh, Seok-Kyeong
    Oh, Jung-Suk
    Cho, Soo-Ah
    [J]. MEDICINA-LITHUANIA, 2021, 57 (11):
  • [23] Comparison of recovery times by using bispectral index monitoring versus end-tidal agent concentration monitoring in patients undergoing inhalational general anaesthesia
    Chaudhuri, Shalini
    Banerjee, Sandipan
    Chattopadhyay, Uddalak
    Hussain, Syed S.
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 : S161 - S168
  • [24] Comparison of recovery times by using bispectral index monitoring versus end-tidal agent concentration monitoring in patients undergoing inhalational general anaesthesia
    Chaudhuri, Shalini
    Banerjee, Sandipan
    Chattopadhyay, Uddalak
    Hussain, Syed S.
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 (SUPPL 3) : S161 - S168
  • [25] Effect of end-tidal carbon dioxide level on the optic nerve sheath diameter measured by transorbital ultrasonography in anesthetized pediatric patients: A randomized trial
    Jang, Young-Eun
    Nam, SeungPyo
    Ji, Sang-Hwan
    Kim, Eun-Hee
    Lee, Ji-Hyun
    Jung, Jae Ho
    Kim, Hee-Soo
    Kim, Jin-Tae
    [J]. PEDIATRIC ANESTHESIA, 2022, 32 (06) : 754 - 763
  • [26] The ED95 of end-tidal sevoflurane concentration for the smooth exchange of the tracheal tube for a laryngeal mask airway is 2.97%La DE95 de la concentration télé-expiratoire de sévoflurane nécessaire au remplacement sans à-coups du tube endotrachéal par un masque laryngé est de 2,97%
    Koichi Takita
    Masahiro Yamane
    Yuji Morimoto
    Osamu Kemmotsu
    [J]. Canadian Journal of Anaesthesia, 2003, 50 (2) : 184 - 188