TECHNIQUES FOR HIGH-RESOLUTION ECHO-PLANAR MR IMAGING OF THE PANCREAS

被引:24
作者
REIMER, P
SAINI, S
HAHN, PF
MUELLER, PR
BRADY, TJ
COHEN, MS
机构
[1] MASSACHUSETTS GEN HOSP, CTR MGH NMR, 32 FRUIT ST, BOSTON, MA 02114 USA
[2] MASSACHUSETTS GEN HOSP, DEPT RADIOL, DIV GASTROINTESTINAL RADIOL, BOSTON, MA 02114 USA
[3] HARVARD UNIV, SCH MED, BOSTON, MA 02114 USA
关键词
MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT; ECHO PLANAR; PULSE SEQUENCES; TISSUE CHARACTERIZATION; PANCREAS; MR; NEOPLASMS; PANCREATITIS;
D O I
10.1148/radiology.182.1.1727278
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent technical advances in echo-planar magnetic resonance (MR) imaging prompted an investigation of these new techniques in pancreatic MR imaging and evaluation of bowel lumen enhancement with an aqueous bowel contrast agent. In 42 subjects (36 healthy, six with pancreatic disease), various T1-weighted inversion-recovery and T2-weighted spin-echo fat-suppressed pulse sequences were assessed with an echo-planar technique implemented with a modified clinical MR imager. Single-excitation imaging (echo time, 26 msec) provided a higher (P < .05) signal-to-noise ratio than did conventional spin-echo and all other echo-planar techniques. In 13 (72%) of 18 healthy subjects who did not undergo administration of the contrast agent, the entire pancreas was distinguished from adjoining bowel. In all 18 subjects who underwent contrast-enhanced imaging, a significantly greater (P < .05) intraluminal signal intensity was apparent with all echo-planar pulse sequences and the entire pancreas was identified. In six patients with pancreatic disease, lesions could be identified by their difference in signal intensity.
引用
收藏
页码:175 / 179
页数:5
相关论文
共 50 条
  • [1] ECHO-PLANAR MR-IMAGING
    EDELMAN, RR
    WIELOPOLSKI, P
    SCHMITT, F
    RADIOLOGY, 1994, 192 (03) : 600 - 612
  • [2] ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    FELMLEE, JP
    GRIMM, RC
    RADIOLOGY, 1993, 189 (01) : 259 - 264
  • [3] NORMAL HEART - EVALUATION WITH ECHO-PLANAR MR-IMAGING
    DAVIS, CP
    MCKINNON, GC
    DEBATIN, JF
    WETTER, D
    EICHENBERGER, AC
    DUEWELL, S
    VONSCHULTHESS, GK
    RADIOLOGY, 1994, 191 (03) : 691 - 696
  • [4] Mucin-producing tumor of the pancreas: Diagnostic value of diffusion-weighted echo-planar MR imaging
    Yamashita, Y
    Namimoto, T
    Mitsuzaki, K
    Urata, J
    Tsuchigame, T
    Takahashi, M
    Ogawa, M
    RADIOLOGY, 1998, 208 (03) : 605 - 609
  • [5] ECHO-PLANAR IMAGING
    DELAPAZ, RL
    RADIOGRAPHICS, 1994, 14 (05) : 1045 - 1058
  • [6] Assessment of fetal lung growth in utero with echo-planar MR imaging
    Duncan, KR
    Gowland, PA
    Moore, RJ
    Baker, PN
    Johnson, IR
    RADIOLOGY, 1999, 210 (01) : 197 - 200
  • [7] ECHO-PLANAR MR IMAGING OF NORMAL AND ISCHEMIC MYOCARDIUM WITH GADODIAMIDE INJECTION
    WENDLAND, MF
    SAEED, M
    MASUI, T
    DERUGIN, N
    MOSELEY, ME
    HIGGINS, CB
    RADIOLOGY, 1993, 186 (02) : 535 - 542
  • [8] BRAIN PARENCHYMA MOTION - MEASUREMENT WITH CINE ECHO-PLANAR MR IMAGING
    PONCELET, BP
    WEDEEN, VJ
    WEISSKOFF, RM
    COHEN, MS
    RADIOLOGY, 1992, 185 (03) : 645 - 651
  • [9] Measurement of the apparent diffusion coefficient in intraductal mucin-producing tumor of the pancreas by diffusion-weighted echo-planar MR imaging
    Irie, H
    Honda, H
    Kuroiwa, T
    Yoshimitsu, K
    Aibe, H
    Shinozaki, K
    Masuda, K
    ABDOMINAL IMAGING, 2002, 27 (01): : 82 - 87
  • [10] CARDIAC ECHO-PLANAR MR-IMAGING - COMPARISON OF SINGLE-SHOT AND MULTIPLE-SHOT TECHNIQUES
    WETTER, DR
    MCKINNON, GC
    DEBATIN, JF
    VONSCHULTHESS, GK
    RADIOLOGY, 1995, 194 (03) : 765 - 770