ACCURACY OF SUBSAMPLING MILL FOR GRANULAR-MATERIALS

被引:4
作者
DICKENS, JW [1 ]
WHITAKER, TB [1 ]
MONROE, RJ [1 ]
WEAVER, JN [1 ]
机构
[1] N CAROLINA STATE UNIV, RALEIGH, NC 27650 USA
关键词
D O I
10.1007/BF02909531
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A subsampling mill was constructed with 19 subsample spouts similar to the 1 or 2 subsample spouts on the conventional subsampling mills. Samples of peanuts, each of which contained 1 kernel made radioactive by neutron activation, were comminuted in the mill. For treatment M the discharge from each spout was kept separate. For treatment R, the discharge from all 19 spouts was blended together in a twin-shelled blender and subdivided with a riffle divider into 16 subsamples which averaged the same weight as the M subsamples. Radioactivity counts/gram of each subsample were measured. Eleven samples were comminuted for each treatment which produced a total of 209 M samples and 176 R samples. An analysis of variance on the pooled data from each treatment showed a mean square error of 1318.3 for the M treatment and 1278.6 for the R treatment. The null hypothesis that the mean square errors for the two treatments are equal was not rejected by the F test (P=0.421). © 1979 The American Oil Chemists' Society.
引用
收藏
页码:842 / 844
页数:3
相关论文
共 5 条
[1]  
DICKENS J W, 1969, Food Technology, V23, P90
[2]   AFLATOXIN CONTROL PROGRAM FOR PEANUTS [J].
DICKENS, JW .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1977, 54 (03) :A225-A228
[3]  
STOLOFF L, 1969, JAOCS, V45, P678
[4]   VARIABILITY OF AFLATOXIN TEST RESULTS [J].
WHITAKER, TB ;
DICKENS, JW ;
MONROE, RJ .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1974, 51 (05) :214-218
[5]  
1975, OFFICIAL METHODS ANA, pCH26