MEASUREMENT OF ENDOGENOUS OXYGEN-UPTAKE RATES OF BREWERS YEASTS

被引:9
|
作者
PEDDIE, FL [1 ]
SIMPSON, WJ [1 ]
KARA, BV [1 ]
ROBERTSON, SC [1 ]
HAMMOND, JRM [1 ]
机构
[1] BREWING IND RES FDN,REDHILL RH1 4HY,SURREY,ENGLAND
关键词
TEST; OXYGEN UPTAKE; YEAST; PROCESS CONTROL;
D O I
10.1002/j.2050-0416.1991.tb01048.x
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The oxygen requirement of brewers' yeast varies with both the yeast strain and the physiological condition of the yeast and it has been suggested that an estimate of the amount required can be obtained from yeast oxygen uptake values (qO2). Using two techniques (a batch aeration method and a continuous aeration method) it has been shown that the qO2 value can change with time during the evaluation, due to physiological changes in the yeast. Since an assessment of the oxygen requirement is dependent on a representative measurement of qO2 value, tests designed to estimate this parameter should incorporate the following features: (i) Access of the yeast to oxygen should be restricted during sampling and at all times prior to analysis, (ii) qO2 measurements should be made immediately before the yeast is pitched in the brewery, (iii) qO2 value should be expressed on a per cell basis in order to eliminate the need for (time consuming) dry weight determinations. Time dependent changes in qO2 values, which take place during the assay, can affect the precision of the test results. It has been found that the use of high concentrations of cells (1-2 g dry weight Litre-1) reduces this error.
引用
收藏
页码:21 / 25
页数:5
相关论文
共 50 条
  • [31] OPTIMIZATION MEASUREMENT OF OXYGEN-UPTAKE RATE OF BCG WITH THE GILSON OXYGRAPH
    VANDENHEUVEL, N
    TIESJEMA, RH
    VANHEMERT, PA
    ANTONIE VAN LEEUWENHOEK JOURNAL OF MICROBIOLOGY, 1981, 47 (02): : 185 - 186
  • [32] SIMPLE, INEXPENSIVE APPARATUS FOR CONTINUOUS MEASUREMENT OF RESPIRATION BY OXYGEN-UPTAKE
    PHILLIPS, DE
    PASSAM, HC
    TROPICAL SCIENCE, 1976, 18 (02): : 125 - &
  • [33] AUTOMATED SYSTEMS FOR MEASUREMENT OF OXYGEN-UPTAKE DURING EXERCISE TESTING
    VERSTEEG, PGA
    KIPPERSLUIS, GJ
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1989, 10 (02) : 107 - 112
  • [34] DESIGN AND EVALUATION OF AN AUTOMATED OXYGEN-UPTAKE RATE MEASUREMENT SYSTEM
    AIDUN, B
    SMITH, DW
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1988, 15 (06) : 1015 - 1021
  • [35] MEASUREMENT OF BACTERIAL OXYGEN-UPTAKE KINETICS BY A MODIFIED RESPIROMETRIC TECHNIQUE
    KING, LR
    PALMER, HJ
    BIOTECHNOLOGY AND BIOENGINEERING, 1989, 33 (07) : 932 - 937
  • [36] POLAROGRAPHIC MEASUREMENT OF OXYGEN-UPTAKE USING LIPOXYGENASE IN REVERSE MICELLES
    HOCHKOEPPLER, A
    PALMIERI, S
    BIOTECHNOLOGY AND BIOENGINEERING, 1990, 36 (07) : 672 - 677
  • [37] THE SIGNIFICANCE OF OXYGEN-UPTAKE RATES ON THE OPERATION OF ACTIVATED-SLUDGE SYSTEMS
    FORSTER, CF
    SURENDRA, M
    WATT, S
    BIOTECHNOLOGY LETTERS, 1980, 2 (07) : 327 - 332
  • [38] OXYGEN-UPTAKE AND OXYGEN DELIVERY IN CIRRHOSIS
    LEHRMAN, SG
    ACEVEDO, JC
    SAVINO, JA
    CERABONA, T
    AGARWAL, N
    MAGUIRE, GP
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04): : A620 - A620
  • [39] LIGHT DEPENDENT OXYGEN-UPTAKE BY ANACYSTIS NIDULANS, STUDIES WITH ENDOGENOUS AND ADDED REDUCTANTS
    KLEINENHAMMANS, JW
    TEERLINK, T
    VANDENBERG, JT
    ACTA BOTANICA NEERLANDICA, 1977, 26 (04): : 285 - 288
  • [40] MEASUREMENT OF OXYGEN-UPTAKE BY THE REVERSED FICK PRINCIPLE AND RESPIRATORY GAS MONITORING - DOES INTRAPULMONARY OXYGEN-UPTAKE ACCOUNT FOR SYSTEMATIC DIFFERENCES BETWEEN METHODS
    WEYLAND, A
    WEYLAND, W
    SYDOW, M
    WEYLAND, C
    KETTLER, D
    ANAESTHESIST, 1994, 43 (10): : 658 - 666