THE IMPACT OF CARBON DIOXIDE CONCENTRATION ON THE HUMAN HEALTH - CASE STUDY

被引:19
作者
Kapalo, P. [1 ]
Domnita, F. [2 ]
Bacotiu, C. [2 ]
Spodyniuk, Nadija [3 ]
机构
[1] Tech Univ Kosice, Dept Tech Bldg Equipment, Fac Civil Engn, Vysokoskolska 4, Kosice 04200, Slovakia
[2] Tech Univ Cluj Napoca, Bldg Serv Fac, Dept Bldg Serv Engn, 21 Decembrie 1989 Blvd 128-130, Cluj Napoca 400604, Romania
[3] Lviv Polytech Natl Univ, Dept Heat & Gas Supply & Ventilat, St Bandery 12, UA-79013 Lvov, Ukraine
关键词
CO2; concentration; heart-beat intensity; blood pressure; pulse; physical activity;
D O I
10.2478/jaes-2018-0008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
From various other studies, it is known that the maximum carbon dioxide concentration in different countries is between 1,000 ppm up to 1,500 ppm. Therefore, the research is focused on indoor environment, namely the production of pollutants from the persons inside office rooms. The article presents the trend of the carbon dioxide concentration from the occupants inside an office. It is examined the carbon dioxide production separately for men and women, for persons of different mass and for persons of different ages. It is also analyzed the carbon dioxide production during a sedentary and physical activities. In parallel with the production of carbon dioxide is presented the monitoring of the human pulse and blood pressure. All these parameters are monitored together with relative humidity and indoor air temperature. The aims of this paper is to describe the partial results of human respiration impact on indoor air quality in closed spaces and to research the connection between carbon dioxide concentration and human health.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 16 条
[1]  
Andrew K. P., 1997, ASHRAE T, V103, P193
[2]  
[Anonymous], 2006, 15251 EN, P51
[3]  
EUROPEAN COMMITTEE FOR STANDARDIZATION, 2007, 13779 EN, P72
[4]   Detection of human effluents by a MOS gas sensor in correlation to VOC quantification by GC/MS [J].
Herberger, S. ;
Herold, M. ;
Ulmer, H. ;
Burdack-Freitag, A. ;
Mayer, F. .
BUILDING AND ENVIRONMENT, 2010, 45 (11) :2430-2439
[5]   Using Experimental Measurements of the Concentrations of Carbon Dioxide for Determining the Intensity of Ventilation in the Rooms [J].
Kapalo, Peter ;
Vilcekova, Silvia ;
Voznyak, Orest .
PRES 2014, 17TH CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1-3, 2014, 39 :1789-+
[6]  
Lis A, 2014, ADV MAT RES, V1020, P585
[7]  
Muntea C, 2015, INT MULTI SCI GEOCO, P843
[8]  
Persily A, 2005, P 10 INT C IND AIR Q, P24
[9]   Oxygen Transport in Human Alveolar Sacs [J].
Przekop, Rafal .
ICHEAP-10: 10TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-3, 2011, 24 :565-570
[10]   Estimating Toxic Risk Exposure to Populations Inside Buildings [J].
Sarrack, Anthony G. .
CISAP5: INTERNATIONAL CONFERENCE ON SAFETY & ENVIRONMENT IN PROCESS & POWER INDUSTRY, PT 1, 2012, 26 :549-554